PROBLEM
O. "ICE" and "SERVICE"
Flashing on LCD
Series
Series
2
2
(600-
)
(600-
)
POSSIBLE CAUSE
Water Valve Energized Longer then
Fifteen Seconds
8-15
Troubleshooting Guides
TEST / ACTION
Check icemaker area for jammed ice cube,
clear jam if present. Check levelness of ice-
maker, level if needed. Check position of fill
cup. Reposition if in ice path.
Check water supply pressure; must be con-
stant 20-100 PSI. If not, instruct customer.
Check water valve operation, opens when
115V AC is applied, closes completely when
115V AC is removed. Water valve Ohms =
160. Replace if defective.