Board Output Test - Maytag 27" Troubleshooting Manual

27” front load washer
Table of Contents

Advertisement

Slide 11

Board Output Test

While in Service Mode, pressing the Spin Speed key will
begin the Board Output Test. This test turns on a specified
output after a key press. Pressing the Spin Speed key again
cancels the test. Only one output can be "on" at any time. All
outputs will be turned off after five (5) minutes of inactivity.
Refer to Technical Data Sheet for Detailed Instructions
Board Output Test
While in Service Mode, pressing the Spin Speed key will begin the Board Output Test. This
test turns on a specified output after a key press. Pressing the Spin Speed key again
cancels the test. Only one output can be "on" at any time. All outputs will be turned off after
five (5) minutes of inactivity.
While in Service Mode follow to check respective function.
When the "Rotary Cycle Selector" is set to "Super Wash" and the "Rotary Cycle Selector"
button is pressed, the Main relay will be toggled (either from "on" to "off" or from" off" to "on").
When the "Rotary Cycle Selector" is set to "Normal" and the "Rotary Cycle Selector" button
is pressed, the hot water valve will be turned on. This output will remain on until the "Rotary
Cycle Selector" button is pressed again to turn off the output. The control will not allow the
machine to fill past the High water level.
When the "Rotary Cycle Selector" is set to "Wrinkle Control" and the "Rotary Cycle
Selector" button is pressed, the cold water valve will be turned on. This output will remain on
until the "Rotary Cycle Selector" button is pressed again to turn off the output. The control
will not allow the machine to fill past the High water level.
When the "Rotary Cycle Selector" is set to "Delicates" and the "Rotary Cycle Selector"
button is pressed, the bleach valve will be turned on. This output will remain on until the
"Rotary Cycle Selector" button is pressed again to turn off the output. The control will not
allow the machine to fill past the High water level.
When the "Rotary Cycle Selector" is set to "Hand Wash" and the "Rotary Cycle Selector"
button is pressed, the pre wash valve will be turned on. This output will remain on until the
"Rotary Cycle Selector" button is pressed again to turn off the output. The control will not
allow the machine to fill past the High water level.
When the "Rotary Cycle Selector" is set to "Quick Wash" and the "Rotary Cycle Selector"
Press