Slide 18 information - Troubleshooting a no fill complaint
No Water Fill
•
Test water fill. Perform Board Output Test.
•
Check to make sure water supply is turned on fully.
•
Check electrical circuit and connections at the Water Valve, and Pressure Switch.
•
Check for kinks in inlet hoses.
•
Check for clogged inlet screens.
•
Visually check hot, cold, bleach and softener water valves separately for fill.
•
Check for low water pressure. May be dependent on pressure entering home. Variations may
occur due to usage in the home at the time machine is used.
•
Check for frozen pipes and hoses.
•
Check resistance of Water Valve coils. (Normal 1.18Kohms; Check resistance of water valve
coils. Check Pin #1 of CN5 and Pin # 1,2,3,4 of CN10.
•
Check for loose connections at the Pressure Switch or on the Machine Control Board, CN3.
(Refer to the component Testing procedure).
26