4-20 Configuring Your Server
IMPORTANT:
Executing "Load Setup Defaults" in BIOS SETUP utility does not
restore the default value for settings related to management LAN of
BMC. To restore the default value, you need to execute Clear BMC
Configuration.
It takes about several tens seconds until initialization completes
after execution of Clear BMC Configuration.
Executing Clear BMC Configuration also clears settings made in
NEC ESMPRO Manager. Before execution, be sure make backup
copy of setting information of NEC ESMPRO Manager.
NOTE:
BIOS SETUP does not save the settings you have made in BMC LAN
Configuration menu.
Event Log Configuration Submenu
Option
System Event Log
Auto Clear Event
Logs
Clear All Event
Logs
Notes on performing Clear BMC Configuration
Executing [Save Custom Defaults/Load Custom Defaults] of
Parameter
[Disabled]
Enabled
Description
System Event Log submenu is
displayed.
If set to "Enabled", logs are
automatically cleared when the error
log area is fulfilled.
Press Enter and select "Yes" to clear
the system event log.
Your Setting
[
]: Factory-set