Download Print this page

Technical Data; Operational Specifications; Environmental Conditions; Power Requirements - Vaisala Thunderstorm LS7002 Brochure & Specs

Advanced total lightning sensor

Advertisement

Technical Data

Operational Specifications

Lightning Type
Cloud (IC) and Cloud-to-ground (CG)
Network Flash Detection Efficiency
Network Median Location Accuracy
Range of Recommended Baseline
Distances Between Sensors
Minimum number of sensors per network
LF Band
Performance Monitoring
Complete automatic system calibration
Remote Configuration
a
IC flash detection efficiency of higher than 50% can be achieved with
network baseline distances shorter than 150 km.
Median network location accuracy can be better than 150 m in the
b
interior of the network.
Performance specifications are applicable to LS7002 networks using the
c
latest version of Vaisala's Total Lightning Processor TLP
Time Synchronization
Source
Accuracy
Dimensions
Weight
Height
Width
Depth
Mounting
Concrete ground pad
Non-ground mounting options available

Power Requirements

AC Power
DC Power
Communication Interface
TCP/IP
64 kbps maximum per data stream depending upon
RS-232 Serial
www.vaisala.com
lighting events and flashes
95% for CG; 50% for IC
a, c
250 m
b, c
15 to 350 km
1kHz-350kHz
and self-test with manual capability
Operational parameters are
remotely configurable
TM
GPS receiver
50 nanoseconds to UTC
37.4 kg
2.2 meters
0.4 m
0.4 m
100VAC-240VAC, 4A max, 50-60Hz
48VDC, 1A max
network geometry and gain settings
maintenance port for optional
on-site connection
Please contact us at
www.vaisala.com/requestinfo
200
580
508
2207
411
Four
919
508

Environmental Conditions

Temperature
Relative Humidity
Wind Speed
Altitude
Hail
Ice
Rain
Support Services
Training, technical support, and spare parts are available
for maintaining optimal network and sensor performance.
Contact your Vaisala Sales Representative for service agreement
information.
Standard Warranty
Vaisala warrants all products manufactured by Vaisala to be free
from defects in workmanship or material for one year from the
date of delivery. Contact your Vaisala Sales Representative for
specific product service warranty details.
This device complies with part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operations.
Scan the code for
more information
253
127
224
39
368
406
269
388
361
406
271
351
13
-40 °C to +55 °C
0 to 100% condensing
Up to 5500 meters
2.0 cm in diameter
8 cm/h at wind speed 65 km/h
Ref. B211284EN-A ©Vaisala 2013
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.
27
0-240 km/h
8 cm

Advertisement

loading