Vaisala HUMICAP HMP155 User Manual (102 pages)
Humidity and Temperature Probe
Brand:
Vaisala
| Category:
Accessories
| Size: 1 MB
Table of Contents
Table of Contents
3
1 About this Document
9
Version Information
9
Related Manuals
9
Documentation Conventions
9
Table Document Versions
9
Table 2 Related Manuals
9
Trademarks
10
Patent Notice
10
2 Product Overview
11
Vaisala HUMICAP Humidity and Temperature Probe HMP155
11
HMP155 Models
11
Table 3 HMP155 Models
11
Humidity Sensor Options
12
Table 4 Humidity Sensors
12
Table 5 Humidity Sensor Types
12
Features and Options
13
Table 6 Analog Output Options
13
Table 7 Models and Available Features
13
Table 8 Heating Options
13
Table 9 Accessories
14
HMP155 Parts
15
Heating Options
15
Figure 1 HMP155 Parts
15
Table 10 Heating Options
15
Chemical Purge Option
16
Warmed Probe Option
16
Figure 2 Decrease of Sensor Gain
17
Extra Sensor Heating (Xheat) Option
18
Additional Temperature Probe Option
19
Figure 3 HMP155 with Additional T-Probe
19
Connection Cover Option
20
Safety
20
Figure 4 HMP155 with Optional Connection Cover
20
ESD Protection
21
Regulatory Compliances
21
3 Installation
22
Mounting in Radiation Shields
22
Mounting HMP155 and DTR13 on Horizontal Sensor Support Arm
22
Table 11 Radiation Shields
22
Figure 5 HMP155 and DTR13 Installation Accessories
23
Mounting HMP155 Inside Radiation Shield DTR503A
26
Figure 6 HMP155 and DTR503A Installation Accessories
27
Installation in Stevenson Screen
32
Installing HMP155
33
Figure 7 HMP155 with T-Probe Installed in Stevenson Screen
33
Wiring HMP155
34
8-Pin Connector
34
Table 12 Vaisala Cables 223283, 220496, 220497, 220498
34
Figure 8 Wiring of HMP155 8-Pin Connector
35
Table 13 Wiring of HMP155 8-Pin Connector
35
Figure 9 HMP155D Block Diagram and Wiring
36
Temporary RS-485 Connection Option
37
Figure 10 HMP155A/E Block Diagram and Wiring
37
4 Operation
38
Interface
38
Serial Line Communication
38
Table 14 Default Serial Communication Settings
38
Connecting HMP155 with Putty Terminal Software
39
Installing Driver for USB Cable
39
HMP155 Commands
41
Table 15 Measurement Commands
42
Table 16 Formatting Commands
42
Table 17 Chemical Purge Commands
42
Table 18 Calibration and Adjustment Commands
42
Table 19 Analog Output Commands
43
Table 20 Other Commands
43
Measurement Commands
44
R Command
44
S Command
44
INTV Command
44
SEND Command
45
SMODE Command
45
Table 21 Output Modes
45
OPEN Command
46
CLOSE Command
46
SDELAY Command
46
SERI Command
47
ADDR Command
47
Formatting Commands
48
FORM Command
48
Table 22 Quantities Measured by HMP155
49
Table 23 Quantities Calculated from Measured Quantities
49
Table 24 FORM Command Modifiers
49
TIME Command
51
Table 25 Symbols in FORM Checksum Equations
51
UNIT Command
52
Chemical Purge Commands
52
PUR Command
52
Extra Sensor Heating (Xheat) Commands
53
XHEAT Command
53
Analog Output Configuration Commands
54
Command
55
AMODE Command
55
Table 26 Analog Output Modes
55
ASEL Command
56
Table 27 Quantities Measured by HMP155
56
Table 28 Quantities Calculated from Measured Quantities
56
AERR Command
57
ATEST Command
58
Pressure Compensation Commands
59
PRES and XPRES Commands
59
System Commands
59
Command
60
ERRS Command
60
FILT Command
61
HELP Command
61
VERS Command
62
RESET Command
63
5 Maintenance
64
HMP155 Maintenance
64
Cleaning
64
Changing HMP155 Probe Filter
64
Changing HUMICAP Sensor
65
Figure 11 Changing INTERCAP/HUMICAP180R/HUMICAPR2 Sensors
66
Errors
67
Table 29 HMP155 Error Messages
67
6 Calibration and Adjustment
68
Overview
68
Push-Button Calibration
69
Figure 12 HMP155 Adjustment Buttons
69
Performing Two-Point Humidity and Temperature Adjustment
70
Performing One-Point Humidity and Temperature Adjustment
71
Passive Output Version Push-Button Calibration
72
Serial Line Calibration
72
Two-Point Humidity Adjustment
72
Two-Point Temperature Adjustment
73
One-Point Humidity and Temperature Adjustment
74
Adjusting and Calibrating Relative Humidity after Sensor Change
74
User Adjustment Commands
75
L Command
76
LI Command
76
CT Command
77
CTA Command
77
CRH Command
78
FCRH Command
78
Typing Calibration Information
78
CTEXT Command
78
CDATE Command
79
Analog Output Adjustment
79
ACAL Command
79
Calibrating and Adjusting with MI70
80
7 Technical Data
82
Measuring Specifications
82
Table 30 Humidity Measurement Performance
82
Table 31 Temperature Measurement Performance
82
Figure 13 HMP155 Accuracy over Temperature Range: Voltage and RS-485
83
Table 32 Dew Point Calculation Specifications
83
Table 33 Quantities Measured by HMP155
83
Environmental Specifications
84
Accuracy of Calculated Variables
84
Table 34 Quantities Calculated from Measured Quantities
84
Table 35 Operating Environment
84
Accuracy of Dew Point Temperature °C
85
Accuracy of Mixing Ratio G/Kg (Ambient Pressure 1013 Mbar)
85
Accuracy of Wet Bulb Temperature °C
85
Accuracy of Dewpoint Measurement
86
Inputs and Outputs
86
Figure 14 Accuracy of Dewpoint Measurement
86
Table 36 Inputs and Outputs
86
Mechanical Specifications
87
Options and Accessories
87
Table 37 Mechanical Specifications
87
Table 38 Options and Accessories
87
Dimensions
89
HMP155 Dimensions
89
Additional Temperature Probe Dimensions
89
Figure 15 Dimensions
89
Figure 16 Additional T-Probe Dimensions
89
Radiation Shield Dimensions
90
Figure 17 DTR503 and DTR13 Dimensions
90
Appendix A: Calculation Formulas
91
Index
95
Technical Support
99
Warranty
99
Product Returns
99
Recycling
99
Advertisement
Vaisala HUMICAP HMP155 User Manual (84 pages)
Humidity and Temperature Probes
Brand:
Vaisala
| Category:
Test Equipment
| Size: 1 MB
Table of Contents
Table of Contents
3
Chapter 1 General Information
7
About this Manual
7
Contents of this Manual
7
Version Information
8
Related Manuals
8
Documentation Conventions
8
Table 1 Manual Revisions
8
Table 2 Related Manuals
8
Safety
9
Regulatory Compliances
9
Recycling
10
Patent Notice
10
Trademarks
10
License Agreement
10
Warranty
11
Chapter 2 Product Overview
13
Introduction to HMP155
13
Table 3 Quantities Measured by HMP155
13
Basic Features and Options
14
Table 4 Quantities Calculated by HMP155
14
Figure 1 HMP155 Probe
15
Structure of the HMP155
15
Additional Temperature Probe Option
16
Figure 2 HMP155 with Additional T-Probe
16
Connection Cover Option
17
Figure 3 HMP155 with Optional Connection Cover
17
Warmed Probe Option
17
Chapter 3 Installation
19
Installation in Radiation Shields
19
Installation in DTR13
19
Figure 4 HMP155 with T-Probe Installed in DTR13
19
Installation in DTR503
20
Figure 5 HMP155 Installed in DTR503
20
Installation in Stevenson Screen
21
Figure 6 HMP155 with T-Probe Installed in Stevenson Screen
21
8-Pin Connector
22
Figure 7 Wiring of HMP155 8-Pin Connector
22
Figure 8 HMP155D Block Diagram and Wiring
23
Figure 9 HMP155A/E Block Diagram and Wiring
23
Temporary RS-485 Connection Option
24
Chapter 4 Operation
25
Getting Started
25
RS-485 Interface
25
Serial Line Communication
26
Table 5 Default Serial Communication Settings
26
Installing the Driver for the USB Cable
27
Terminal Application Settings
28
Figure 10 Putty Terminal Application
29
List of Serial Commands
30
Table 6 Measurement Commands
30
Table 7 Formatting Commands
30
Table 8 Chemical Purge Commands (Optional)
30
Table 10 Setting and Testing the Analog Outputs
31
Table 11 Other Commands
31
Table 9 Calibration and Adjustment Commands
31
Measurement Commands
32
Sdelay
32
Send [Addr]
32
Seri [Baud][Parity][Data][Stop]
33
Intv
34
Smode
34
Table 12 Selection of Output Modes
34
Form
35
Formatting Commands
35
Table 13 FORM Command Modifiers
35
Table 14 Symbols Used in FORM Checksum Equations
36
Time
37
Unit [M/N]
37
PRES and XPRES
38
Pressure Compensation Commands
38
Filt [0.1
39
System Commands
39
Help
41
Errs
42
Reset
42
Vers
42
Amode
43
Analog Output Configuration Commands
43
Asel
44
Aerr
45
Atest
45
Addr
46
Close
46
Open
46
Sensor Functions
47
Chemical Purge (Optional)
47
Automatic Chemical Purge (Interval Purge)
48
Chemical Purge in Power up
48
Figure 11 Decrease of Sensor Gain
48
Manual Chemical Purge
48
Starting and Configuring Chemical Purge
49
Pur
49
Sensor Heating
50
Setting Humidity Sensor Heating
50
Xheat
51
Chapter 5 Maintenance
53
Periodic Maintenance
53
Cleaning
53
Changing the Probe Filter
53
Changing the Sensor
54
Figure 12 Changing the HUMICAP 180/180R Sensors
55
Error States
56
Table 15 Error Messages
56
Technical Support
57
Product Returns
57
Chapter 6 Calibration and Adjustment
59
Figure 13 HMP155 Adjustment Buttons
60
Push-Button Calibration
61
Two-Point Humidity and Temperature Adjustment
61
One-Point Humidity and Temperature Adjustment
63
Passive Output Version Push-Button Calibration
64
Serial Line Calibration
65
Two-Point Humidity Adjustment
65
Two-Point Temperature Adjustment
66
Relative Humidity Adjustment after Sensor Change
67
Fcrh
67
One-Point Humidity and Temperature Adjustment
67
User Adjustment Commands
68
Feeding Adjustment Information
68
Ctext
69
Cdate
69
Analog Output Adjustment
69
Acal [0/1]
70
MI70 Check and Adjustment
70
Chapter 7 Technical Data
73
Performance
73
Relative Humidity
73
Table 16 Relative Humidity Performance
73
Temperature
74
Figure 14 Accuracy over Temperature Range: Voltage and RS-485
74
Table 17 Temperature Performance
74
Operating Environment
75
Table 18 Operating Environment
75
Calculated Variables
76
Accuracies of Calculated Variables
76
Accuracy of Dew Point Temperature °C
76
Accuracy of Mixing Ratio G/Kg (Ambient Pressure 1013 Mbar)
76
Table 19 Calculated Variables
76
Accuracy of Wet Bulb Temperature °C
77
Accuracy of Dew Point Measurement
77
Inputs and Outputs
77
Figure 15 Accuracy of Dew Point Measurement
77
Table 20 Outputs
77
Mechanics
78
Table 21 Average Current Consumption (+15 VDC, Load 100 Kohm)
78
Table 22 Operating Voltage and Settling Time
78
Table 23 Mechanical Specifications
78
Options and Accessories
79
Table 24 Options and Accessories
79
Dimensions in MM (Inches)
80
HMP155 Probe
80
Additional Temperature Probe
80
Figure 16 Probe Dimensions
80
Figure 17 Additional Temperature Probe Dimensions
80
Appendix Acalculation Formulas
81
Vaisala HUMICAP HMP155 User Manual (86 pages)
Humidity and Temperature Probe
Brand:
Vaisala
| Category:
Measuring Instruments
| Size: 0 MB
Table of Contents
Table of Contents
3
Chapter 1 General Information
7
About this Manual
7
Contents of this Manual
7
Version Information
8
Related Manuals
8
General Safety Considerations
8
Table 1 Manual Revisions
8
Table 2 Related Manuals
8
Feedback
9
Product Related Safety Precautions
9
Regulatory Compliances
9
Electromagnetic Compatibility
9
Recycling
10
Trademarks
10
License Agreement
10
Warranty
11
Chapter 2 Product Overview
13
Introduction to HMP155
13
Table 3 Quantities Measured by HMP155
13
Basic Features and Options
14
Table 4 Calculated Quantities Measured by HMP155
14
Structure of the HMP155
15
Figure 1 HMP155 Probe
15
Additional Temperature Probe Option
16
Figure 2 HMP155 with Additional T-Probe
16
Warmed Probe Option
17
Chapter 3 Installation
19
Installation in Radiation Shields
19
Installation in DTR13
20
Figure 3 HMP155 with T-Probe Installed in DTR13
20
Installation in DTR503
21
Figure 4 HMP155 Installed in DTR503
21
Installation in Stevenson Screen
22
Figure 5 HMP155 with T-Probe Installed in Stevenson Screen
22
8-Pin Connector
23
Figure 6 Wiring of HMP155 8-Pin Connector
23
Temporary RS-485 Connection Option
24
Figure 7 Pins Connected to Pt100 (Passive Output Version)
24
Chapter 4 Operation
25
Getting Started
25
RS-485 Interface
25
Serial Line Communication
26
Table 5 Default Serial Communication Settings for the User Port
26
Installing the Driver for the USB Cable
27
Terminal Application Settings
28
Figure 8 Putty Terminal Application
29
List of Serial Commands
30
Table 6 Measurement Commands
30
Table 7 Formatting Commands
30
Table 8 Chemical Purge Commands (Optional)
30
Table 9 Calibration and Adjustment Commands
31
Table 10 Setting and Testing the Analog Outputs
31
Table 11 Other Commands
31
Getting Measurement Message from Serial Line
32
Send [Addr]
32
Sdelay
33
Formatting Serial Line Message
33
Changing Quantities and Units
33
Form
33
Table 12 FORM Command Modifiers
34
Unit [M/N]
35
Pressure Compensation Setting
35
Time
36
Time [Hh MM Ss]
36
Serial Settings
37
Seri [Baud][Parity][Data][Stop]
37
Smode
37
Intv
38
Table 13 Selection of Output Modes
38
Data Filtering
39
Filt [0.1
39
Help
41
Errs
42
Vers
42
Resetting Transmitter Using Serial Line
42
Reset
42
Formatting Analog Output
43
Analog Output Settings
43
Amode
43
Asel
44
Atest
45
Aerr
45
Addr
46
Open
46
Close
47
Sensor Functions
47
Chemical Purge (Optional)
47
Automatic Chemical Purge (Interval Purge)
48
Manual Chemical Purge
48
Chemical Purge in Power up
48
Figure 9 Decrease of Sensor Gain
48
Starting and Configuring Chemical Purge
49
Pur
49
Sensor Heating
50
Setting Humidity Sensor Heating
50
Xheat
50
Chapter 5 Maintenance
53
Periodic Maintenance
53
Cleaning
53
Changing the Probe Filter
53
Changing the Sensor
54
Figure 10 Changing the Sensor
55
Error States
56
Table 14 Error Messages
56
Technical Support
57
Return Instructions
57
Vaisala Service Centers
58
Calibration and Adjustment
59
Figure 11 HMP155 Adjustment Buttons
60
Push-Button Calibration
61
Two-Point Humidity and Temperature Adjustment
61
One-Point Humidity and Temperature Adjustment
63
Passive Output Version Push-Button Calibration
64
Serial Line Calibration
65
Two-Point Humidity Adjustment
65
Two-Point Temperature Adjustment
66
Relative Humidity Adjustment after Sensor Change
67
Fcrh
67
One-Point Humidity and Temperature Adjustment
67
User Adjustment Commands
68
Feeding Adjustment Information
69
Ctext
69
Cdate
69
Analog Output Adjustment
69
Acal [0/1]
70
MI70 Check and Adjustment
70
Chapter 7 Technical Data
73
Performance
73
Relative Humidity
73
Temperature
74
Operating Environment
74
Figure 12 Accuracy over Temperature Range: Voltage and RS-485
74
Calculated Variables
75
Accuracies of Calculated Variables
75
Accuracy of Dewpoint Temperature °C
75
Accuracy of Mixing Ratio G/Kg (Ambient Pressure 1013 Mbar)
75
Table 15 Calculated Variables
75
Accuracy of Wet Bulb Temperature °C
76
Accuracy of Dewpoint Measurement
76
Figure 13 Accuracy of Dewpoint Measurement
76
Inputs and Outputs
77
Mechanics
77
Options and Accessories
78
Table 16 Options and Accessories
78
Dimensions in MM (Inches)
79
HMP155 Probe
79
Additional Temperature Probe
79
Figure 14 Probe Dimensions
79
Figure 15 Additional Temperature Probe Dimensions
79
Appendix Acalculation Formulas
81
Advertisement
Vaisala HUMICAP HMP155 Quick Manual (2 pages)
Humidity and Temperature Probe
Brand:
Vaisala
| Category:
Measuring Instruments
| Size: 1 MB
Advertisement
Related Products
Vaisala HMP110 series
Vaisala HMP110T
Vaisala HMP1
Vaisala HMP60 series
Vaisala HUMICAP HMP45
Vaisala HUMICAP HMP46
Vaisala HUMICAP HMP4
Vaisala HUMICAP HMP5
Vaisala HUMICAP HMP8
Vaisala HMP Series
Vaisala Categories
Transmitter
Measuring Instruments
Accessories
Weather Station
Test Equipment
More Vaisala Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL