HighPoint RocketRAID 3522 SATAII User Manual page 34

Sataii host adapter
Hide thumbs Also See for RocketRAID 3522 SATAII:
Table of Contents

Advertisement

Web RAID Management Interface
3) Click the
Delete
button.
Note: An array in use by the operating system cannot be deleted. Any data stored on
a deleted array will be inaccessible
Array Maintenance – Rebuilding/Verifying/Modifying RAID arrays
Rebuilding a Failed Array
When an array member in a redundant array fails, the array will be listed as broken. A
broken array will be automatically rebuilt using available-spare disks. However, if you
have no spare disks configured, you can still rebuild by manually adding an Available
Disk to the array. To add a disk to a broken array:
1) Select menu
"Manage -
2) Highlight the desired RAID array
3) Click the "Maintenance" button.
4) Click the
"Add
Disk" button.
5) If the disk is successfully added to the array, rebuild process will start
automatically. A progress bar will be displayed.
Note: If the system utilizes hot-swap capable enclosures, you can add new physical
disks to the RocketRAID card in order to rebuild or modify an existing array, using the
"Rescan" feature.
Reminder: When adding disks manually, make sure to initialize the disk (see Preparing
Hard Disks).
Only initialized disks can be used to rebuild RAID arrays.
Verifying an Array
For a RAID 1 or RAID1/0 array, verify process compares the data of one mirror pair
with the other. For RAID 5, verify process calculates RAID5 parity and compares it to
the parity data on the array. Verification checks each sector on a drive. Periodic
verification of an array allows the disk drive firmware to take corrective actions on
problem areas on the disk, minimizing the occurrence of uncorrectable read and write
errors.
To verify an array:
1) Select menu
"Manage -
5-5
Array".
Array".

Advertisement

Table of Contents
loading

Table of Contents