I.

COMPLETE THE FAN INSTALLATION:

This insert comes complete with a fan, speed control and temperature limit switch assembly already installed. This fan is
equipped with a three-prong (grounding) plug attached to the end of the 8 ft. fan electrical cord for protection against shock
hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not remove the grounding prong
from the plug. Do not allow any excess fan cord to touch the firebox.
1.
Attach the limit switch on the left side of the millivolt board under the firebox.
2.
Plug fan cord into the nearest, properly grounded receptacle.
Note: The fan will not operate unless the speed control has been turned on. The fan will not turn on until sufficient heat is applied to the
thermostatic control switch. The fan will then turn on and off automatically as the fireplace heat and cools. Adjust fan to desired speed
while it is running.
NOTE: THIS FAN SYSTEM, WHEN INSTALLED, MUST BE ELECTRICALLY CONNECTED AND GROUNDED IN ACCORDANCE WITH LOCAL
BUILDING CODES, OR IN THE ABSENCE OF LOCAL BUILDING CODES, WITH THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70.
CAUTION:
WHEN INSTALLATION OF THE MILLIVOLT BOARD IS COMPLETE, CHECK TO ENSURE
THAT THERE ARE NO WIRES, FLEX LINES, ETC., TOUCHING THE FAN TERMINALS.