Da-Lite Tensioned Executive Electrol Instruction Book page 5

Hide thumbs Also See for Tensioned Executive Electrol:
Table of Contents

Advertisement

Tensioned Executive Electrol
120V Wiring Diagram
Capacitor
Black
Black
Internal
Wiring
External Wiring
to Be Completed
By Installer
Black
Up
Off
Down
Side View Of
Switch & Box
Installation
®
Black
Blue
Down
Red (Up)
Adj.
White
Black
(Down)
Red
Green
(Ground)
Junction Box Mounted In
Screen Case, In Which Internal
Wiring Terminates In
White, Black And Red Leads
Black With Yellow
AC Common
Operating Switch,
AC Hot
Switch Box, And
120VAC 60Hz.
Plate Furnished
1 Amp. Max
With Screen. (SPDT)
Center Off
With
This Switch Cannot Be Used With L. V .C.
240 Volt Wiring Diagram
For Standard Wall Switch:
Da-Lite offers two styles of 240 volt wall
switches for standard operation. Please see
wiring diagram included in wall switch box
included with screen.
Down Limit Switch
Door Solenoid Limit Switch
Motor: 120V.60 Cycles 1/10 HP Intermittent
Duty With Auto-Reset Thermal Protector
Blue
Solenoid
White
Up Limit Switch
(Operated By Door)
In Multiple Control Installations This Switch
Is Replaced By The Low Voltage Control,
Operated From Push-Button Stations.
5