4.7.4
Timer Reset Panel, Cabin Panel, Motion Detector,
Flash Beacon
The wiring procedure is common to all the above-mentioned units.
Cable to use
Cable MPYC-7
(between respective
unit and BR-520)
Cable total length
Cabin Panel: max. 300 m
Timer Reset Panel: max. 150 m
1) Unfasten four screws
to remove rear cover.
Timer Reset Panel
Max. length of single cable: 40 m
Max. length: of all cables: 150 m
Cabin Panel
Max. length of single cable: 80 m
Max. length of all cables: 300 m
2) Process cable and connect cable
to WAGO terminal block.
Use terminal opener (inside
Processor Unit) to open terminals.
(Shown: Timer Reset Panel)
Description
3) Close rear cover. Fasten
cable to clamp with cable
tie (supplied).
4. INSTALLATION
4-13