1. MAIN ALARM PANEL
1.3

BNWAS Display

The BNWAS display is divided into the seven areas described below.
Watch time
interval
Watch time interval
countdown timer
(Colored bar flows
downward with time)
Operating mode
The current operating mode. The possible indications are Auto, Manual ON, and Man-
ual OFF.
Power indication
The power indications shows the power being supplied to the system.
• Power AC/DC: Both AC and DC power
• Power AC: AC power
• Power DC: DC power
• Power --/--: At equipment startup, or communication failure (between Processor
Unit and Main Alarm Panel).
System status indicator
The system status indicator rotates when the system is normal, and appears on all dis-
plays. If the indicator is not rotating, there can be a problem with the system. Contact
a FURUNO agent or dealer for information.
Backup officer indication/selection
You select the backup officer with the SEL key. The current selection is underlined.
Help area
The help area shows all operational events, operation guides and error messages.
See section 1.8 Help Area.