Cisco Prisma II Installation And Operation Manual page 118

Optical amplifiers
Hide thumbs Also See for Prisma II:
Table of Contents

Advertisement

Alarm Parameters
Introduction
The following table describes the alarm parameters for this module. Alarm
parameters are dependent on module type.
Alarm Name
ICIM
(LCI)
Abbrev.
Laser Bias
LasBias *
Current *
Optical Input
InPwr *
Power
Optical
OutPwr *
Output *
Laser
LasTemp
Temperature
Laser
Enable
Enabled
Status
Internal
IntPs
Power
Supply
Status
* These are user alarms whose limits can be changed by the user. All other alarms are
module alarms whose limits are set at the factory and cannot be changed by the user.
A-4
Function
Major
Low
Laser bias
-32 A
current
Optical input
-15.0
power
dBm
Optical output
-1.0
dBm
Laser
-9.0°C
temperature
Module on or
-
off
Power supply
-
fault
Module Parameter Descriptions
Threshold Values
Minor
Minor
Major
Low
High
-32 A
-0.1 A
-0.01 A
-5.0
20.0
45.0
dBm
dBm
dBm
-0.7
0.7
1.0
dBm
dBm
dBm
-9.0°C
30.0°C
45.0°C
-
-
-
-
-
-
Hys-
teresis
High
0.001 A
1.0
dBm
0.1
dBm
1.0°C
-
-
78-739260-01 Rev F