Func.
Name
Code
P072
Position range (Forward)
P073
Position range (Reverse)
P075
Positioning mode selection
P077
Encoder
timeout
p100
EzSQ user parameter
U(00) ~ U(31)
~
P131
P140
EzCOM number of data
P141
EzCOM destination 1 adderss
P142
EzCOM destination 1 register
P143
EzCOM source 1 register
P144
EzCOM destination 2 adderss
P145
EzCOM destination 2 register
P146
EzCOM source 2 register
P147
EzCOM destination 3 adderss
P148
EzCOM destination 3 register
P149
EzCOM source 3 register
P150
EzCOM destination 4 adderss
P151
EzCOM destination 4 register
P152
EzCOM source 4 register
P153
EzCOM destination 5 adderss
P154
EzCOM destination 5 register
P155
EzCOM source 5 register
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
"P" Function
0 to +268435455(Higher 4-digits
displayed)
–268435455 to 0(Higher 4-digits
displayed)
00...With limitation
01...No limitation (shorter route)
disconnection
0.0 to 10.0 s
Each set range is 0~65535
1 to 5
1 to 247
0000 to FFFF
0000 to FFFF
1 to 247
0000 to FFFF
0000 to FFFF
1 to 247
0000 to FFFF
0000 to FFFF
1 to 247
0000 to FFFF
0000 to FFFF
1 to 247
0000 to FFFF
0000 to FFFF
83
Description
P004 is to be set 00 or 01
Run
Defaults
Mode
Lnitial data
Units
Edit
+2684354
Pulse
55
s
-2684354
Pulse
55
s
-
00
s
1.0
0.
-
5
-
-
1
-
0000
-
0000
-
2
-
0000
-
0000
-
3
-
0000
-
0000
-
4
-
0000
-
0000
-
5
-
0000
-
0000