Hitachi WJ200 Series Quick Reference Manual page 63

Wj200 series inverter single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

Func.
Name
Code
B060
Maximum-limit level of window
comparator (O)
B061
Minimum-limit level of window
comparator (O)
B062
Hysteresis width of window
comparator (O)
B063
Maximum-limit level of window
comparator (OI)
B064
Minimum-limit level of window
comparator (OI)
b065
Hysteresis width of window
comparator (OI)
b070
Operation level at O
disconnection
b071
Operation level at OI
disconnection
b075
Ambient temperature setting
B078
Watt-hour clearance
b079
Watt-hour display gain
B082
Start frequency
B083
Carrier frequency
B084
Initialization mode (parameters
or trip history)
B085
Country for initialization
B086
Frequency scaling conversion
factor
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
"b" Function
Description
Set range, {Min.-limit level (b061) +
hysteresis width (b062)x2} to 100 %
(Minimum of 0%)
Set range, 0 to {Max.-limit level
(b060) - hysteresis width
(b062)x2} % (Maximum of 0%)
Set range, 0 to {Max.-limit level
(b060) - Min.-limit level (b061)}/2 %
(Maximum of 10%)
Set range, {Min.-limit level (b064 +
hysteresis width (b065)x2} to 100 %
(Minimum of 0%)
Set range, 0 to {Max.-limit level
(b063) - hysteresis width
(b065)x2} % (Maximum of 0%)
Set range, 0 to {Max.-limit level
(b063) - Min.-limit level (b064)}/2 %
(Maximum of 10%)
Set range, 0 to 100%, or "no"
(ignore)
Set range, 0 to 100%, or "no"
(ignore)
Set range is,
-10~50 °C
Two option codes:
00...OFF
01...ON (press STR then clear)
Set range is,
1.~1000.
Sets the starting frequency for the
inverter output, range is 0.10 to 9.99
Hz
Sets the PWM carrier (internal
switching frequency), range is 2.0 to
15.0 kHz
Select initialized data, five option
codes:
00...Initialization disabled
01...Clears Trip history
02...Initializes all Parameters
03...Clears Trip history and
initializes all parameters
04...Clears Trip history and
initializes all parameters and
EzSQ program
Select default parameter values for
country on initialization, two option
codes:
00...area A
Specify a constant to scale the
displayed frequency for D007
monitor, range is 0.01 to 99.99
62
Run
Mode
Lnitial data
Edit
01...area B
Defaults
Units
100.
%
0.
%
0.
%
100.
%
0.
%
0.
%
no
-
no
-
°C
40
00
-
1.
0.50
Hz
2.0
kHz
00
00
1.00