DECORATIVE
STRAP
FAN ASSEMBLY
STRAP SLOT
Figure 17
10. This completes the installation of your ceiling fan.
How to Wire Your Ceiling
Fan - SW22 Wall Control
WARNING
!
To avoid possible electrical shock, be sure
electricity is turned off at the main fuse box
before wiring.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for
advice, as it must be grounded for safe
operation.
This control is designed to operate two ceiling
fans, and not any accessory light kits. The SW22
speed control is rated for 3.0 amps at 120 volts.
NOTE: Electrical connections should be in
accordance with the National Electrical Codes and
all Local Codes. Before starting, disconnect
power to the circuit at the fuse box or circuit
breaker panel.
1. Set the SW22 Wall Control in the off position (full
counter-clockwise), and pull off the knob.
2. Connect one BLACK wire from the SW22 Wall
Control to the supply HOT lead with a wire
connector (provided) (Figure 18).
3. Connect the other BLACK wire from the SW22 Wall
Control to the Black LOAD wire with a wire
connector (provided) (Figure 18) .
NOTE: Use wire connectors (supplied) to secure
electrical connections.

Control Operation:

BUCKLE
Figure 18
4. Position the faceplate (not provided) onto the
5. Press knob onto the shaft and rotate counter-
6. Restore power at the main fuse box or circuit
Figure 19
The SW22 Wall Control has one high speed and one
low speed setting. From the OFF position, rotate the
knob in the clockwise direction to the high position.
For low speed, rotate the knob clockwise to the next
position. Turn the fans off by fully rotating the knob
counter-clockwise to the OFF potion (Figure 20).
Figure 20
11
BLK
HOT
BLK
speed control. Using the two 6-32 screws supplied
with the faceplate, screw the faceplate and speed
control to the wall outlet box (Figure 19).
clockwise to the full-OFF position.
breaker panel.
WALL OUTLET
BOX
SW22 WALL CONTROL
FACEPLATE
6-32 SCREWS (2)
120 VAC SUPPLY
(User Supplied)