Cascaded 32-Bit Counter; Table 2.17:32-Bit Counter Control Bit; Power Input; Figure 2.11:Location Of Power P1 And P2 - Advantech UNO-3074 User Manual

Celeron m/ pentium m embedded automation computer with four pci slot extensions
Table of Contents

Advertisement

2.7.10 Cascaded 32-bit Counter

Y ou can also cascade counter 0 and counter 1 together as one 32-bit coun-
ter/timer, and it's configured by control bit - CTR32Set.
Table 2.17: 32-bit Counter Control Bit
0
1
Note:
UNO-3074 provides built-in examples to show how
to deliver counter functionality. Refer to console
mode examples in C:\Program Files\Advan-
tech\UNO\UNO_IsaDIO\Examples\Console. (Please
install DI/O driver from the UNO CD to use these
examples)

2.8 Power Input

UNO-3074 comes with a Phoenix connector that carries 16~36 VDC exter-
nal power input, and features reversed wiring protection. Therefore, it will
not cause any damage to the system by reversed wiring of ground line and
power line. (Please refer to Figure 2.11 for location of power input)
The UNO-3074 supports two individual power inputs (P1/P2). (Please
refer to Appendix A.7 for wiring of P1 and P2)
UNO-3074 User Manual
Disable (Default)
Cascade counter 0 and counter 1 into one 32-bit counter
Figure 2.11: Location of Power P1 and P2