Covers
Covers
Removing the drive motor covers
The drive motor covers are fitted with two screws
each. The associated brake release covers are
fitted with one screw each.
1. On wheelchairs equipped with lights and
indicators, remove the front and upper chassis
cover. (See page 7-9).
2. Remove the drive motor cover, it is attached
with two screws (see fig.).
3. Remove the brake release cover, it is attached
with one screw (see fig.).
4. On wheelchairs equipped with lights and
indicators, separate the indicators' cabling at
the contact on the cabling. This is positioned
on the inside of the chassis, next to the seat
lift.
For this task the following tools are necessary:
1
Allen key 3 mm.
1
Allen key 2,5 mm.
The drive motor cover is fitted with two screws.
The brake release cover is fitted
with one screw.
The connector on the front indicator cabling.