Checking Circuit Pack Configuration - Avaya G650 Installing

Hide thumbs Also See for G650:
Table of Contents

Advertisement

Figure 102: Sample port network status screen for Cabinet 1—Avaya S8500
status port-network 1
Major
Minor
PN Alarms Alarms Alarms
1
1
TDM Service
Bus
State
A
in
B
in
PKT
1
Command:

Checking circuit pack configuration

The list configuration report provides a list of circuit packs connected to the configuration and
recognized by the software. To check circuit pack configuration:
1. Type list configuration all and press Enter.
2. Verify the screen displays list configuration similar to
configuration screen — Page 4, Avaya S8700 Multi-Connect on page
software is communicating with each circuit pack (except power supply circuit packs). Do
not attempt to correct any problems until after the diagnostic tests that you run later in the
configuration tests.
3. Note any boards with a VINTAGE column entry of NO BOARD or CONFLICT.
A u indicates unassigned ports, and a number indicates the port has been translated.
Warning Carrier
Locs
0
195
01A
01B
Control
Dedicated
Channel
Tones
y
n
n
y
Service
Major
State
Alarms
in
PORT NETWORK STATUS
PN Control
Active
Standby
up
up
1
TONE/
CLOCK
01B
01A
Minor
Bus
Alarms
Faults
n
n
0
FIBER-
LINK
Endpoints
B-PNC 01B02-03E04 standby
1
A-PNC 01A01-01E04 active
Service
System
State
Clock
in
standby
in
active
Open Bus
Leads
0
Figure 103: Sample system
230. Make sure the
Issue 2 January 2005
Mode
System
Tones
standby
active
229

Advertisement

Table of Contents
loading

Table of Contents