HP ProLiant DL385 Server User Guide
Configuring memory options
Language selection
For more information on RBSU, refer to the HP ROM-Based Setup Utility User
Guide on the Documentation CD or the HP website
(http://www.hp.com/servers/smartstart).
Using RBSU
The first time you power up the server, the system prompts you to enter RBSU
and select a language. Default configuration settings are made at this time and
can be changed later. Most of the features in RBSU are not required to set up the
server.
To navigate RBSU, use the following keys:
To access RBSU, press the F9 key during power up when prompted in the
upper right corner of the screen.
To navigate the menu system, use the arrow keys.
To make selections, press the Enter key.
Auto-configuration process
The auto-configuration process automatically runs when you boot the server for
the first time. During the power-up sequence, the system ROM automatically
configures the entire system without needing any intervention. During this
process, the ORCA utility, in most cases, automatically configures the array to a
default setting based on the number of drives connected to the server.
IMPORTANT: RBSU automatically saves settings when you press the
Enter key. The utility does not prompt you for confirmation of settings
before you exit the utility. To change a selected setting, you must select
a different setting and press the Enter key.
NOTE: The server may not support all the following examples.
NOTE: If the boot drive is not empty or has been written to in the past,
ORCA does not automatically configure the array. You must run ORCA
to configure the array settings.