Table A-5: Is the iLO Remote Console Displaying Error Information?
Answer
Solution
No
An iLO problem exists. Refer to the HP Integrated Lights-Out User Guide that
ships with the server blade.
Yes
Error and event logs are available for diagnosis. Determine the next action by
observing POST progress and error messages. Use the iLO system status
page or use the local I/O cable connectors, depending on the server blade
model, to help determine the problem. Refer to "Server Error Messages" in this
appendix, and the HP ProLiant Servers Troubleshooting Guide for a complete
description of POST error messages.

Server Blade and Blade Sleeve Power Troubleshooting

The power troubleshooting table contains a matrix of possible power conditions that
can exist. Use the optional diagnostic station to power a ProLiant BL30p server blade
in the left bay of a blade sleeve, with the blade sleeve laying on a flat surface.
IMPORTANT: The ProLiant BL30p blade sleeve is required when powering a ProLiant BL30p
server blade outside of the rack. Only one ProLiant BL30p server blade may be installed in the
blade sleeve when receiving power from the diagnostic station.
IMPORTANT: If you are connecting to a ProLiant BL30p server blade, the server blade must
be installed in the left slot of the blade sleeve on a flat surface.
NOTE: It is not necessary to remove the blade sleeve cover as all LEDs are visible through
the blade sleeve cover.
HP ProLiant BL30p Server Blade Setup and Installation Guide
Server Blade Troubleshooting
A-13