HP ProLiant BL35p User Manual
Hide thumbs Also See for ProLiant BL35p:
Table of Contents

Advertisement

Quick Links

HP ProLiant BL35p Server Blade
User Guide
August 2006 (Fourth Edition)
Part Number 379104-004

Advertisement

Table of Contents
loading

Summary of Contents for HP ProLiant BL35p

  • Page 1 HP ProLiant BL35p Server Blade User Guide August 2006 (Fourth Edition) Part Number 379104-004...
  • Page 2 © Copyright 2005, 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
  • Page 3: Table Of Contents

    Power up the server blade ........................12 Power down the server blade........................12 Remove the server blade .......................... 13 Setup............................14 Installing the HP BladeSystem components ....................14 Verifying system components ........................14 Connecting to the network ........................14 Installing server blade options ........................14 Using the diagnostic station ........................
  • Page 4 Automatic Server Recovery ......................56 ROMPaq Utility ..........................56 Integrated Lights-Out Manager technology ..................56 Erase Utility ..........................56 HP Systems Insight Manager ......................57 Management Agents........................57 Redundant ROM support ........................ 57 USB support..........................57 Diagnostic tools ............................58 HP Insight Diagnostics ........................
  • Page 5 Grounding methods to prevent electrostatic discharge .................. 85 Specifications ..........................86 Environmental specifications ........................86 Server specifications ..........................86 Technical support........................87 Before you contact HP..........................87 HP contact information ..........................87 Customer self repair..........................87 Acronyms and abbreviations......................89 Index............................92...
  • Page 6: Component Identification

    Component identification In this section Server blade components .......................... 6 Sleeve board and server blade LED locations ....................9 Local I/O cable ............................. 10 Server blade enclosure bay numbering ..................... 10 Server blade enclosure compatibility ......................11 Server blade components Front panel components and LEDs Item Description...
  • Page 7 Item Description Status NIC 2 LED* Green = Network linked Green flashing = Network activity Off = No link or activity Hard drive activity LED Green/Flashing = Activity Off = No activity Power On/Standby button Green = On Amber = Standby (auxiliary power available) Off = Off Local I/O port**...
  • Page 8: Internal Components

    Internal components Item Description Fan assembly connectors (2) Processor socket 2 DIMM bank A (populated) Adapter card connectors (2) Battery Processor socket 1 (populated) DIMM bank B Hard drive cable connector System maintenance switch (SW1) Fan assembly Hard drive cage Component identification 8...
  • Page 9: System Maintenance Switch

    System maintenance switch Position Default Function Off = iLO security is enabled. On = iLO security is disabled. Off = System configuration can be changed. On = System configuration is locked. Reserved Reserved Off = Power-on password is enabled. On = Power-on password is disabled.
  • Page 10: Local I/O Cable

    Each server blade enclosure requires a pair of interconnect modules to provide network access for data transfer. Interconnect modules reside in the far right and far left bays of the server blade enclosure. Be sure to review server blade bay numbering to determine the HP ProLiant BL35p Server Blade external network connections on the interconnects.
  • Page 11: Server Blade Enclosure Compatibility

    IMPORTANT: When looking at the rear of the enclosure, server blade bay numbering is reversed. Server blade enclosure compatibility The HP ProLiant BL35p Server Blades require the support of an HP BladeSystem p-Class sleeve in a server blade enclosure with enhanced backplane components (enhanced server blade enclosure). The enhanced server blade enclosure also provides a single rear iLO connector for single-cable remote management of all installed HP ProLiant BL35p Server Blades.
  • Page 12: Operations

    CAUTION: Always observe iLO alerts before initiating a power-up override to prevent a hot-plug power supply fault and possible loss of system power. For more information, refer to the HP Integrated Lights-Out User Guide.
  • Page 13: Remove The Server Blade

    IMPORTANT: Remote power procedures require the most recent firmware for the power enclosure and server blade enclosure management modules. For the most recent firmware, refer to the HP website (http://www.hp.com/go/support).
  • Page 14: Setup

    HP website (http://www.hp.com/go/bladesystem/powercalculator). Connecting to the network To connect the HP BladeSystem to a network, each server blade enclosure must be configured with a pair of network interconnects to manage signals between the server blades and the external network. For more information about interconnect options, refer to the HP website (http://www.hp.com/go/bladesystem/interconnects).
  • Page 15: Using The Diagnostic Station

    • The NIC 2 LED is not functional. • For more information, refer to the documentation that ships with the diagnostic station or refer to the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info). Installing a server blade CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any installation procedure.
  • Page 16 Install the HP BladeSystem p-Class sleeve. The sleeve is fully inserted when it locks into place. NOTE: It is not necessary to remove server blades already installed in the sleeve before installing the new sleeve. CAUTION: Sleeves and other components are keyed to fit only one way in the enclosure bay. If a component does not slide easily into the bay, check the orientation of the component before reinsertion.
  • Page 17: Completing The Configuration

    Remove the 3U server blade blank from the sleeve for the lower server blade installation. Completing the configuration To complete the server blade and HP BladeSystem configuration, refer to the hardware installation and configuration poster that ships with the server blade enclosure.
  • Page 18: Hardware Options Installation

    Multifunction network adapter option......................30 Processor option Use these instructions to install an AMD Opteron™ processor into a supported HP ProLiant p-Class server blade. NOTE: Some server blade models ship with one processor installed. Use these instructions to install an optional second processor.
  • Page 19 CAUTION: Do not bend or damage the pins beneath the processor. CAUTION: Be sure that the processor socket locking lever is closed after the processor is installed. The lever should close without resistance. Forcing the lever closed can damage the processor and socket, requiring system board replacement.
  • Page 20: Memory Option

    Each processor has a bank consisting of two DIMM slots. The server blade supports up to 8 GB of memory. CAUTION: Use only HP DIMMs. DIMMs from other sources may adversely affect data integrity. Observe the following DIMM installation guidelines: All DIMMs must be the same type.
  • Page 21: Ata Hard Drive Option

    Install the DIMM. ATA hard drive option Use these instructions to install up to two ATA hard drives in the HP ProLiant BL35p Server Blades. This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
  • Page 22 be sure to disconnect the server blade from the diagnostic station before installing internal components. CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. The drive cage assembly lower drive bay is designated as the primary hard drive bay and must be populated first.
  • Page 23 Set the jumper on the hard drive to CS, so that the drive device ID is determined by the hard drive cable. Install the hard drive. IMPORTANT: Be sure the hard drive label is facing up when installed in the drive cage assembly. Install the center plate and cover plate.
  • Page 24 IMPORTANT: Install the optional second hard drive before replacing the cover plate. Connect the hard drive cable to the hard drives. IMPORTANT: Be sure the hard drive cable is connected to the hard drives as illustrated. Hardware options installation 24...
  • Page 25: Sas Hard Drive Option

    For the complete power down and server blade removal procedures, refer to the server blade documentation that shipped with the server blade or the server blade documentation on the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info). To install the component: Power down the server blade (on page 12).
  • Page 26 Remove the cover plate and, if necessary, the center plate. Install the hard drive. IMPORTANT: Be sure the hard drive label is facing up when installed in the drive cage assembly. Install the center plate and cover plate. Hardware options installation 26...
  • Page 27 IMPORTANT: Install the optional second hard drive before replacing the cover plate. Connect the hard drive cable to the hard drives. IMPORTANT: Be sure the hard drive cable is connected to the hard drives as illustrated. Hardware options installation 27...
  • Page 28: Dual Port Fibre Channel Adapter (2-Gb) Option

    Supported SAN and associated software • For more detailed SAN configuration information for the server blade, refer to: The model-specific QuickSpecs document located on the HP ProLiant p-Class server blade products • web page at the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info) The HP StorageWorks SAN documentation at the HP website •...
  • Page 29 CAUTION: Be sure that you have the current version of the system ROM. Without the correct firmware version, the server and hardware options may not function properly. For the most current version of the ROM, go to the HP website (http://www.hp.com/support). Power down the server blade (on page 12).
  • Page 30: Multifunction Network Adapter Option

    Install the FC adapter. Refer to Internal components (on page 8) for the location of the FC adapter connectors. The HP ProLiant BL35p Server Blade requires specific Microsoft® Windows® SAN drivers to support an optional dual port Fibre Channel adapter.
  • Page 31 CAUTION: Be sure to lift the board straight up. Lifting one edge of the board at a time may damage the connectors. Install the multifunction network adapter. Install the FC adapter, if necessary. Hardware options installation 31...
  • Page 32: Local I/O Cabling

    Local I/O cabling In this section Using the local I/O cable........................32 Local administration using iLO ......................... 32 Connecting locally to a server blade with video and USB devices ..............33 Using the local I/O cable The local I/O cable enables the user to perform server blade administration, configuration, and diagnostic procedures in two ways: Connecting locally to the server blade iLO interface •...
  • Page 33: Connecting Locally To A Server Blade With Video And Usb Devices

    Connect the local I/O cable to the I/O port on the server blade. CAUTION: Disconnect the local I/O cable when not in use. The port and connector do not provide a permanent connection. Rear iLO connector performance degrades when the local I/O cable is connected, even if the iLO connector on the cable is not in use.
  • Page 34: Server Blade Deployment Using Local Media Devices

    NOTE: For this configuration, a USB hub is not necessary. To connect additional devices, use a USB hub. Connect the local I/O cable to the server blade. Connect the video connector to a monitor. Connect a USB mouse to one USB connector. Connect a USB keyboard to the second USB connector.
  • Page 35 NOTE: Use a USB hub when connecting a USB diskette drive and/or USB CD-ROM drive to the server blade. The USB hub provides additional connections. Item Description Server blade Monitor USB hub USB CD-ROM drive or USB diskette drive USB keyboard USB mouse Local I/O cabling 35...
  • Page 36: Configuration And Utilities

    Configuration and utilities In this section SAS BIOS configuration utility........................36 Server blade deployment tools ......................... 47 Configuration tools ..........................54 Management tools..........................56 Diagnostic tools ............................. 58 Remote support and analysis tools......................59 Keeping the system current ........................59 SAS BIOS configuration utility SAS BIOS features The SAS BIOS is the bootable ROM code that manages SAS hardware resources.
  • Page 37: Configuration Utility Screens

    The following messages can appear during the boot process: • Adapter removed from boot order! This message displays when an adapter was removed from the system or was relocated behind a PCI bridge. • Adapter configuration may have changed, reconfiguration is suggested! This message displays when fewer than four adapters are in the boot order list and more adapters exist than are shown.
  • Page 38 Removing an adapter from the Boot Order list by moving the cursor to the Boot Order field of the • adapter, and then pressing Del. Changes must be saved before exiting the screen. The Adapter List screen is also the gateway to three other screens: The Global Properties screen (on page 38) •...
  • Page 39 To access the Exit Menu screen, press Esc. • Adapter Properties screen Use the Adapter Properties screen to view information about the adapter and determine whether the adapter is to be controlled by the OS driver, the BIOS, or both. To access the Adapter Properties screen, use the arrow keys to move the cursor to an adapter in the Adapter List field on the Adapter List screen, and then press Enter.
  • Page 40 Select New Array Type screen This screen describes the types of RAID volumes that can be created. Move the cursor to either the Create Raid 1 Volume field or the Create Raid 0 Volume field, and then press Enter to display the Create New Array screen.
  • Page 41 View Array screen The View Array screen displays the current array configuration and provides access to the Manage Array screen. To view the next array, press Alt+N. • To perform management tasks on this array, move the cursor to the Manage Array field, and then •...
  • Page 42 SAS Topology screen The SAS Topology screen provides basic information about each device connected to the adapter and provides the ability to identify the physical device in the system that corresponds to a device in the list. Scroll horizontally to view all the information listed for a device. To access this screen, select the SAS Topology link on the Adapter Properties screen.
  • Page 43 This screen also provides access to the Format and Verify screens. To reach either of these screens, move the cursor to the appropriate field, and then press Enter. Device Format screen Use the Format screen to format a particular device. To access this screen, press Enter in the appropriate field on the Device Properties screen.
  • Page 44: Performing Configuration Tasks

    If the logical block addresses (LBAs) can be reassigned or must be reassigned, the following prompt appears after pressing Enter: Reassign the block? (Yes, No, All, nonE, Cancel) The reassignment options are as follows: Yes—Reassign only this block. If another block must be reassigned in the future, display the prompt •...
  • Page 45 Each drive must have 512-byte blocks. • Drives with removable media are not supported. • The volume must have at least two drives but no more than eight drives. • To create a RAID 0 volume: On the Adapter List screen, select an adapter. On the Adapter Properties screen, select RAID Properties.
  • Page 46 For each drive in the volume, move the cursor to the RAID Disk column for that drive, and then press +, -, or Space bar. The No in that field changes to Yes, and the value in the Array Size field changes to reflect the new size of the volume.
  • Page 47: Server Blade Deployment Tools

    (http://h18002.www1.hp.com/support/files/server/us/index.html). Linux OS users can download these components from the HP website (http://www.hp.com/products/servers/linux). For information on how to use these components with a Linux OS, refer to the HP website (http://h18000.www1.hp.com/products/servers/linux/documentation.html). ProLiant p-Class Advanced management iLO Advanced is a standard component of ProLiant p-Class server blades that provides server health and remote server blade manageability.
  • Page 48: Network-Based Pxe Deployment

    The IP address is assigned by a DHCP server on a network. The p-Class tab enables you to control specific settings for the HP BladeSystem. iLO also provides web- based status for the HP BladeSystem configuration.
  • Page 49 1.3.1_07 1.3.1_08 1.4.1 for Windows® users only 1.4.2 for Linux users only Access the Java™ Runtime Environment versions at the HP website (http://java.sun.com/products/archive/index.html). DHCP server (IP address assignment) • AMD Athlon™ XP processor (700 MHz or greater recommended), AMD Athlon™ 64 processor, •...
  • Page 50: Deployment Methods

    NICs can be configured to boot PXE. For more information, refer to "Network-based PXE deployment (on page 48)." NOTE: Actual NIC numeration depends on several factors, including the OS installed on the server blade. HP recommends using one of the following methods for PXE deployment: HP ProLiant Essentials RDP ("HP ProLiant Essentials Rapid Deployment Pack"...
  • Page 51 It enables you to perform imaging or scripting functions and maintain software images. For more information about the RDP, refer to the HP ProLiant Essentials Rapid Deployment Pack CD or refer to the HP website (http://www.hp.com/servers/rdp).
  • Page 52 iLO virtual CD-ROM To deploy with a boot CD: Do one of the following: Insert the boot CD into the client PC that is using the iLO Remote Console. • Use iLO to create an image file of the boot CD. •...
  • Page 53 The server blade provides FC support for SAN implementations. This solution uses an optional FCA that offers redundant SAN connectivity and optimization for HP StorageWorks products. The server blade is also compatible with certain third-party SAN products. For more information, refer to the documentation that ships with the FCA option.
  • Page 54: Configuration Tools

    • Language selection • For more information on RBSU, refer to the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website (http://www.hp.com/servers/smartstart). Using RBSU The first time you power up the server blade, the system prompts you to enter RBSU and select a language.
  • Page 55: Re-Entering The Server Serial Number And Product Id

    For more information about BIOS Serial Console, refer to the BIOS Serial Console User Guide on the Documentation CD or the HP website (http://www.hp.com/servers/smartstart). Re-entering the server serial number and product ID After you replace the system board, you must re-enter the server serial number and the product ID.
  • Page 56: Management Tools

    ASR increases server availability by restarting the server within a specified time after a system hang or shutdown. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable ASR from the HP SIM console or through RBSU.
  • Page 57: Hp Systems Insight Manager

    ROM. USB support HP provides both standard USB support and legacy USB support. Standard support is provided by the OS through the appropriate USB device drivers. Before the OS loads, HP provides support for USB devices through legacy USB support, which is enabled by default in the system ROM. HP hardware supports USB version 1.1 or 2.0, depending on the version of the hardware.
  • Page 58: Diagnostic Tools

    Diagnostic tools HP Insight Diagnostics HP Insight Diagnostics is a proactive server blade management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server blade installations, troubleshoot problems, and perform repair validation.
  • Page 59: Remote Support And Analysis Tools

    • From within HP Insight Diagnostics (on page 58) • For more information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack. Remote support and analysis tools HP Instant Support Enterprise Edition ISEE is a proactive remote monitoring and diagnostic tool to help manage your systems and devices, a feature of HP support.
  • Page 60: Resource Paqs

    (http://h18000.www1.hp.com/support/files/index.html). Change control and proactive notification HP offers Change Control and Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products. For more information, refer to the HP website (http://h18023.www1.hp.com/solutions/pcsolutions/pcn.html).
  • Page 61: Care Pack

    Care Pack HP Care Pack Services offer upgraded service levels to extend and expand standard product warranty with easy-to-buy, easy-to-use support packages that help you make the most of your server investments. Refer to the Care Pack website (http://www.hp.com/hps/carepack/servers/cp_proliant.html). Configuration and utilities 61...
  • Page 62: Troubleshooting

    To obtain the guide, refer to any of the following sources and then select the HP ProLiant Servers Troubleshooting Guide: The server-specific Documentation CD •...
  • Page 63: Important Safety Information

    WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components. Important safety information Familiarize yourself with the safety information in the following sections before troubleshooting the server. Important safety information Before servicing this product, read the Important Safety Information document provided with the server.
  • Page 64: Warnings And Cautions

    Warnings and cautions WARNING: Only authorized technicians trained by HP should attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board.
  • Page 65: Symptom Information

    NOTE: To verify the server configuration, connect to the System Management homepage and select Version Control Agent. The VCA gives you a list of names and versions of all installed HP drivers, Management Agents, and utilities, and whether they are up to date.
  • Page 66: Diagnostic Steps

    Diagnostic steps To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section, "Start diagnosis flowchart (on page 66)," and follow the appropriate diagnostic path. If the other flowcharts do not provide a troubleshooting solution, follow the diagnostic steps in "General diagnosis...
  • Page 67: General Diagnosis Flowchart

    General diagnosis flowchart The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of the problem, or if the other flowcharts do not fix the problem, use the following flowchart. Item "Symptom information (on page 65)" "Loose connections (on page 65)"...
  • Page 68 • (http://h18023.www1.hp.com/support/files/server/us/romflash.h tml) "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) • Maintenance and service guides for p-Class server blades, located on the Documentation CD or the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info)
  • Page 69: Server Blade Power-On Problems Flowchart

    Server blade power-on problems flowchart Symptoms: The server does not power on. • The system power LED is off or amber. • The health LED is red or amber. • Troubleshooting 69...
  • Page 70 "General diagnosis flowchart (on page 67)" "Loose connections (on page 65)" Power Calculator on the HP website (http://www.hp.com/go/bladesystem/powercalculator) HP BladeSystem Maintenance and Service Guide located on the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info) Integrated Lights-Out User Guide located on the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info) Server maintenance and service guide located on the HP website (http://www.hp.com/products/servers/proliant-bl/p-class/info)
  • Page 71: Post Problems Flowchart

    POST problems flowchart Symptoms: Server does not complete POST • NOTE: The server has completed POST when the system attempts to access the boot device. Server completes POST with errors • Troubleshooting 71...
  • Page 72 CD or the HP website (http://www.hp.com/products/servers/proliant- bl/p-class/info) "Port 85 and iLO messages" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) "General memory problems are occurring" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support)
  • Page 73: Os Boot Problems Flowchart

    OS boot problems flowchart There are two ways to use SmartStart when diagnosing OS boot problems on a server blade: Use iLO to remotely attach virtual devices to mount the SmartStart CD onto the server blade. • Use a local I/O cable and drive to connect to the server blade, and then restart the server blade. •...
  • Page 74 Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) Controller documentation • "HP Insight Diagnostics (on page 58)" or in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) •...
  • Page 75: Server Fault Indications Flowchart

    * See the server blade OS boot problems flowchart (on page 73) Server fault indications flowchart Symptoms: Server boots, but a fault event is reported by Insight Management Agents (on page 57) • Server boots, but the internal health LED, external health LED, or component health LED is red or •...
  • Page 76 (http://www.hp.com/products/servers/proliant-bl/p-class/info) • "HP contact information (on page 87)" "HP Insight Diagnostics (on page 58)" or in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support) "Hardware problems" in the HP ProLiant Servers Troubleshooting •...
  • Page 77: Post Error Messages And Beep Codes

    POST error messages and beep codes Introduction For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website (http://www.hp.com/support). Troubleshooting 77...
  • Page 78 WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary information in the server documentation before removing, replacing, reseating, or modifying system components. Troubleshooting 78...
  • Page 79: Regulatory Compliance Notices

    Regulatory compliance notices In this section Regulatory compliance identification numbers ................... 79 Federal Communications Commission notice ..................... 79 Declaration of conformity for products marked with the FCC logo, United States only........80 Modifications............................81 Cables ..............................81 Canadian notice (Avis Canadien) ......................81 European Union regulatory notice ......................
  • Page 80: Class A Equipment

    Hewlett-Packard Company • P. O. Box 692000, Mail Stop 530113 Houston, Texas 77269-2000 1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded • or monitored.) For questions regarding this FCC declaration, contact us by mail or telephone: Hewlett-Packard Company •...
  • Page 81: Modifications

    Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment. Cables Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
  • Page 82: Disposal Of Waste Equipment By Users In Private Households In The European Union

    Disposal of waste equipment by users in private households in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
  • Page 83: Korean Notice

    Do not operate controls, make adjustments, or perform procedures to the laser device • other than those specified herein. Allow only HP Authorized Service technicians to repair the unit. • The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976.
  • Page 84: Taiwan Battery Recycling Notice

    Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, please use the public collection system or return them to HP, an authorized HP Partner, or their agents.
  • Page 85: Electrostatic Discharge

    Electrostatic discharge In this section Preventing electrostatic discharge......................85 Grounding methods to prevent electrostatic discharge ................85 Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices.
  • Page 86: Specifications

    Specifications In this section Environmental specifications ........................86 Server specifications ..........................86 Environmental specifications Specification Value Temperature range* Operating 10°C to 35°C (50°F to 95°F) Shipping -40°C to 60°C (-40°F to 140°F) Storage -20°C to 60°C (-4 to 140°C) Maximum wet bulb temperature 30°C (86°F) Relative humidity (noncondensing)**...
  • Page 87: Technical Support

    HP's customer self-repair program offers you the fastest service under either warranty or contract. It enables HP to ship replacement parts directly to you so that you can replace them. Using this program, you can replace parts at your own convenience.
  • Page 88 A convenient, easy-to-use program: An HP support specialist will diagnose and assess whether a replacement part is required to address • a system problem. The specialist will also determine whether you can replace the part. For specific information about customer replaceable parts, refer to the maintenance and service •...
  • Page 89: Acronyms And Abbreviations

    Acronyms and abbreviations ABEND abnormal end Automatic Server Recovery BIOS Basic Input/Output System double data rate DHCP Dynamic Host Configuration Protocol electrostatic discharge Fibre Channel Fibre Channel adapter input/output International Electrotechnical Commission Integrated Lights-Out Integrated Management Log Acronyms and abbreviations 89...
  • Page 90 Internet Protocol ISEE Instant Support Enterprise Edition keyboard, video, and mouse light-emitting diode Network Bootstrap Program network file system network interface controller ORCA Option ROM Configuration for Arrays OSEM Open Services Event Manager POST Power-On Self Test ProLiant Support Pack Preboot Execution Environment RAID redundant array of inexpensive (or independent) disks...
  • Page 91 Remote Desktop Protocol RILOE Remote Insight Lights-Out Edition read-only memory storage area network small form-factor pluggable Systems Insight Manager SNMP Simple Network Management Protocol TCP/IP Transmission Control Protocol/Internet Protocol TFTP Trivial File Transfer Protocol unit identification Version Control Agent WEBES Web-Based Enterprise Service Wired for Management Acronyms and abbreviations 91...
  • Page 92: Index

    Index connection problems 65 connectors 6, 8, 10 contacting HP 87 activating an array 46 Create New Array screen 40 Adapter List screen 37 creating a network boot diskette 53 Adapter Properties screen 39 CSR (customer self repair) 87 adapters 8, 28...
  • Page 93 Manage Array screen 41 HP BladeSystem p-Class sleeve 9 Management Agents 57 HP Insight Diagnostics 58 management tools 47, 56 HP ProLiant Essentials Foundation Pack 57 managing an array 46 HP Systems Insight Manager, overview 57 memory slots 8 HP Technical Support 87...
  • Page 94 18 View Array screen 41 server selector switches 28 virtual CD-ROM 52 service notifications 65 virtual floppy 53 setting up a network 48 virtual power 12 sleeve, HP BladeSystem p-Class 9, 15 Virtual Power button 12 Index 94...
  • Page 95 warnings 64 Web-Based Enterprise Service 59 Index 95...

Table of Contents