Each condition in Table A-7 is determined by the corresponding LED located on
either the blade sleeve board or the system board.
Table A-7: Power Troubleshooting Table
Blade Sleeve
Power LED
On
On
Off
Off
Fibre Channel Troubleshooting
The FC LED located on the blade sleeve board shows FC status as follows:
•
On = Normal
•
Off = Critical
System Configuration Switch Procedures
When you perform troubleshooting steps, this guide may instruct you to perform the
following procedures:
•
Clear the system configuration.
•
Access the redundant ROM.
HP ProLiant BL30p Server Blade Setup and Installation Guide
Power Converter
Module LED
On
Off
Off
On
Server Blade Troubleshooting
Possible Reasons
The power is good.
A power problem exists
with the server blade.
or
The power converter
module needs replacing.
Power problem with the
diagnostic station.
or
The blade sleeve board
needs to be replaced.
The blade sleeve board
needs to be replaced.
A-15