Server Blade Troubleshooting
8. Change position 6 of SW1 to off.
9. Repeat steps 4 through 6.
IMPORTANT: When the server blade boots after NVRAM is cleared, a delay of up to
2 minutes is normal. During this delay, the system appears non-functional. Do not attempt
any procedures during the delay.
Accessing the Redundant ROM
If the system ROM is corrupted, you can set the system to use the backup version or
redundant ROM.
To use the redundant ROM:
1. Power down the server blade:
a. Press the Power On/Standby button on the front of the server blade.
b. Use the virtual power button feature in the iLO remote console.
2. Disconnect the server blade from all power sources:
a. Remove the server blade from the server blade enclosure and set it on a flat,
level surface.
b. Disconnect the server blade from the diagnostic station.
3. Change positions 1, 5, and 6 of SW1 to on.
4. Install the server blade into the server blade sleeve and connect the server blade
to system power:
a. Install the server blade in the server blade enclosure.
b. Connect the server blade to the diagnostic station.
5. Power up the server blade:
a. Press the Power On/Standby button on the front of the server blade.
b. Use the virtual power button feature in the iLO remote console.
As soon as the server blade powers up, it emits two beeps.
6. Repeat steps 1 and 2.
A-18
HP ProLiant BL30p Server Blade Setup and Installation Guide