HP ProLiant BL30p Setup And Installation Manual page 93

Hide thumbs Also See for ProLiant BL30p:
Table of Contents

Advertisement

Table A-4: Is the Server Blade Health LED Solid Green?
Answer
Possible Reasons
No, it is flashing
The server blade is still in POST. If
green.
the flashing continues after
1 minute, the following conditions
may apply:
HP ProLiant BL30p Server Blade Setup and Installation Guide
Nonvolatile RAM (NVRAM)
may be corrupted.
The system ROM may be
corrupted.
Both the system ROM and
redundant ROM may be
corrupted.
Server Blade Troubleshooting
continued
Possible Solutions
Wait for the server blade to complete
POST.
Clear the system configuration. Refer to
the "Clearing the System Configuration"
section in this appendix.
Switch to the redundant ROM. Refer to
the "Accessing the Redundant ROM"
section in this appendix.
If the health LED is still not solid green,
do one of the following:
Use the optional diagnostic station
to power the server blade and use
the iLO remote console to continue
the diagnosis.
Use the optional diagnostic station
to power the server blade and use
the local I/O cable connectors,
depending on the server blade
model, to continue the diagnosis.
Use the iLO system status page to
help determine the problem.
Contact an authorized service
provider for replacement parts and
service.
continued
A-11