HOW TO
Selecting Test Features

Setting up Signaling Bits

Setting up Signaling Bits
When transmitting 2.048 Mb/s signals with timeslot-16 CAS (PCM30 or
PCM30CRC) multiframing the state of A,B,C,D signaling bits can be set.
The signaling bits of all timeslots are set to the user-defined 4 bit value.
When transmitting a DS1 framed, structured signal the values of the
A,B signaling bits for D4 and SLC-96 payloads, and A,B,C,D signaling
bits for ESF payloads can be defined.
Transmit a 2 Mb/s signal with user-defined signaling bits
DSn Operation
1 Choose
PDH/DSn
2 Choose SIGNAL
on the
PCM30CRC
3 If UNSTRUCTURED is chosen set the 2M CAS ABCD bits value on
the
MAIN SETTINGS
If STRUCTURED is chosen set the 2M CAS ABCD bits value on the
STRUCTURED SETTINGS
34
display.
on the
TRANSMIT
and PAYLOAD TYPE
2 Mb/s
MAIN SETTINGS
display.
display.
or
PCM30
display.