Generating Overhead Sequences - HP OMNIBER 718 37718A User Manual

Dsn/sonet operation
Table of Contents

Advertisement

Description
HOW TO:
Selecting Test Features

Generating Overhead Sequences

Generating Overhead Sequences
You may insert a pattern into a functional group of overhead bytes for
testing or troubleshooting purposes.
1 Set up the SONET transmit interface and payload required. See
"Setting SONET Transmit Interface" page 4.
2 Choose the type of sequence required.
SINGLE RUN - runs the sequence once and then stops.
REPEAT RUN - runs the sequence repeatedly until STOPPED is
chosen.
3 Choose the overhead type as required.
SOH- Section Overhead
LOH- Line Overhead
POH - Path Overhead
4 Choose the byte or bytes of overhead required.
5
Set up the required number of data patterns and the number of
frames in which each data pattern should appear.
Your sequence is derived from up to 5 blocks of hexadecimal data. Each
block can be transmitted in up to 64,000 frames.
The data and the number of frames are set using
INCREASE DIGIT
.
DECREASE DIGIT