Set Part 2 Zones

This menu allows you to program which zones are to be
monitored when an area has been turned Part 2 On. By
default all zones are monitored when in Part On 2 Mode.
Use this option to set which zones should not be monitored
in Part On 2 mode.
1.
Enter [Master PIN] + [MENU]
2.
Enter [3] + [0] + [4] + [OK]. The keypad will display
the Zn= prompt which will flash indicating that you
are in data entry mode.
Any zone(s) which are currently set as Part 2 zones
will not be displayed. Zones that are displayed will
be a active zones when the system is armed in Part
On 2 mode.
If your system is configured for multiple areas the
area Icon for the current area will also be displayed.
3.
To set a Part 2 zone , enter the zone number
and then press [OK] . The zone indicator will
be extinguished. To remove a Part 2 zone, type
the zone number and then press [OK]. The zone
indicator will appear in the display.
1 2 3
4.
Repeat step 2 for any additional Part 2 zones you
require.
5. Press [OK] to save and exit, or press [MENU] to exit
without saving.
In the above example, zones 1,2,3,5,7 and 8 will be
i
active when the system is armed in Part 2 mode.
Note
Zones 4 and 6 will not be active.
Inputs > Commands >

Smoke Sensor Reset

If your system has smoke sensors fitted, they may be
powered by a special output on the panel which can be
manually reset by master users. Use this function to reset
your smoke detectors if a false alarm occurs.
1.
Enter [Master PIN] + [MENU]
2.
Enter [3] + [0] + [5] + [OK]. The keypad will display
the word BUSY for 10 seconds while the smoke
sensors are reset.
3.
The keypad will automatically return to the menu
when all smoke detectors in the area have been
reset.
If your system is configured for multiple areas you
i
may be asked to select the area to reset.
Note
Bosch Security Systems 10/07 BLCC500U FTR1.01
Pt2-zn
MENU 3-0-4
Zn=
1
5
7 8
fire-r
MENU 3-0-5
Busy
Inputs > Zone Properties >

Zone Name

This menu allows the master user to program the zone
names. Up to 16 characters can be entered for each zone
name. Use the [←] and [→] keys to scroll the cursor left
and right to view the entire zone name.
The text programming procedure is very similar to that of
most mobile phones. Refer the Programming Text section
on page 10 for more details.
Zone names are stored with associated events in the
system's history log. This enables accurate auditing of
events at a later time if required. Names are also used when
reporting alarms and arm /disarm events in SMS and other
text based reporting formats.
Each zone has a default name which can be changed if
desired. The default names are as follows.
D E FAU LT ZO NE NA ME S
Zone Number
1
2
16
Table 10: Default Zone Names
1.
Enter [Master PIN] + [MENU]
2.
Enter [3] + [1] + [0] + [OK]. The keypad will display
the Zn = prompt. Enter the zone number you want
to program, then press [OK].
3.
The keypad will display the current Zone Name.
Use the [←] and [→] keys to view the existing
Zone name. The cursor position is indicated by the
flashing character in the name. It is possible to edit
a single character in the name without re-enetering
the entire name.
4.
Use the 0 to 9, [←] and [→] keys to change the Zone
Name text as required. At any time you can use the
[↑] and [↓] keys to scroll through the complete list of
available characters.
5.
To clear all text from the cursor position to the right,
press the [OFF] key.
6.
When the Zone Name is complete, press [OK] to save
and exit, or press [MENU] to exit without saving.
Solution16
User Guide
i
zn AME
MENU 3-1-0
Default Name
Zone 1
Zone 2
Zone 16
Zn=
Zone 1
19