Walk Test All Zones; Walk Test A Single Zone; Output Options; Output Status - Bosch Solution 16i User Manual

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Solution16
User Guide
i
Inputs > Input Testing >

Walk Test All Zones

This menu allows you to test all zones within an area at the
same time. To successfully walk test each zone, you must
open and close each zone.
1.
Enter [Master PIN] + [MENU]
2.
Enter [3] + [9] + [0] + [OK]. The keypad will display
a list of all zones to be tested. If your system is
configured for multiple areas then you may be
prompted to select the area to test.
1 2 3 4 5 6 7 8
3. Open and close each zone that needs to be tested.
A zone that has been successfully tested will no
longer be displayed on the keypad display.
When all zones have been tested, the keypad will
display PASS.
4. Press [OK] to exit
Inputs > Input Testing >

Walk Test A Single Zone

This menu allows you to select a single zone to be tested
via walk test.
1.
Enter [Master PIN] + [MENU]
2.
Enter [3] + [9] + [1] + [OK]. The keypad will display
the Zn = prompt. Enter the zone number you want
to test, then press [OK].
2
3. Open and close the zone to be tested. If the zone
test was sucessful, the keypad will display PASS.
The system will also chirp the sirens for 1 second if
the zone test was sucsessful making it easier for one
person to do the test.
4. Press [OK] to exit when finished.
20
tstzns
MENU 3-9-0
test
PASS
tst-zn
MENU 3-9-1
Zn=
test
PASS

Output Options

The control panel can have up to 8 outputs. Four outputs
are available as standard with an additional four available
when the optional output expander is fitted.
Outputs are used to operate sirens, strobe lights etc and
can also be used to control automatic doors and gates.
Your installer will advise you on the exact makeup and
configuration of your system.
Outputs > Commands >

Output Status

This menu allows you to view the the current status of each
output.
1.
Enter [Master PIN] + [MENU]
2. Enter [4] + [0] + [0] + [OK]. The keypad will display
the Op = prompt. Enter the output number you
want to view, then press [OK].
3. The keypad will now display the status of the
selected output. There are 3 posible states.
IS OFF - output is OFF,
IS ON - Output is ON and
CONTRB - Connection Trouble. If conection trouble
is shown there may be a problem with an output
device on the system. In this case you should
contact your installer for further information.
The keypad will display the following when output 3
is OFF.
The keypad will display the following when output 2
is ON.
2
The keypad will display the following when output 3
is in troble.
3
4. Press [OK] to exit.
Outputs > Commands >
Turn Output On/Off
This menu allows you to manually control system outputs
that have been programmed by your installer. Outputs can
be programmed to control sirens, strobe lights, outside
lighting, pool pumps, watering systems etc.
StAtus
MENU 4-0-0
OP=
Is off
Is ON
ConTrb
On-Off
MENU 4-0-1
Bosch Security Systems 10/07 BLCC500U FTR1.01