5-2-6 CCD Image Adjustment (Low Temperature)
For this adjustment, use the same conditions as those specified in 5-2-2 Iris Adjustment (Coarse Adjustment)
SPEC.
Automatic writing
Procedure)
(1) Carry out CCD image adjustment (low temperature) in the following procedure.
ST EP PROCEDURE
CCD IMAGE ADJUST MENT
1
1) Make the setting shown at right.
2) Perform storing.
(press the PAUSE button.)
2
1) Make the setting shown at right.
2) Perform storing.
(press the PAUSE button.)
MONIT OR
CS Function MD ADDR DT
2
08
ST
3013
--
RD
2
08
ST
3014
--
RD
20
SERVICE MODE / ADJUSTMENT
Microcomputer operation
Image adjustment (low temperature)
Adjustment is completed.
Completion with ST :05, NG with ST :09
Adjustment data writing.
Adjustment is completed.
Completion with ST :05, NG with ST :09
DC10 E, DC20 E