Permanently changing a group of parameters
A permanent change to a group of parameters is performed by
temporarily overriding a group of parameters and then sending a
scanner-unique Define Mode (JA) command to save the values to
a specified mode.**
The permanent parameter changes remain in effect until a SCSI
or power-on reset occurs.
The following table illustrates how the use of a scanner-unique JA
command can be used to permanently change a group of current
mode parameters:
ACTION
Scanner is in Mode 1
Host executes SCSI Send command
with 2FX300BX
Host executes SCSI Send command
with 4JA
Host executed SCSI Send command
with 4HA
Host executes SCSI Send command
with 1HA
Scanner is in Mode 1
Host executes SCSI Send command
with 2FX300BX4JA
Host executed SCSI Send command
with 4HA
Host executes SCSI Send command
with 1HA
* Parameter default value.
** The value(s) may be saved to the current mode or any of the
other modes.
RESULT
Compression
Resolution
3*
200*
2
300
2
300
3*
200*
3*
200*
2
300
2
300
3*
200*
6-17