Hardware Reference
PWR02 AC PSU
PWR05 AC and DC
PSUs
C613-03092-00 REV J
LED
State
Fault
Red
Key features are:
Hot-swappable and load sharing
■
Physical dimensions
■
•
Height: 40.9 mm
•
Width: 193 mm
•
Depth: 130 mm
Do not combine PWR01 and PWR02 PSUs in the same switch.
■
Universal 100–240 V AC 47/63 Hz input
■
Maximum continuous current draw: 2.2 A at 100 V, 1.1 A at 230 V at full-
■
rated load
Maximum inrush surge current (cold start at 25º C/77º F): 33 A at 115 V
■
The following LEDs report operations and faults on the PWR02 PSU.
LED
State
PWR
Green
Fault
Red
Key features are:
Hot-swappable and load sharing
■
Physical dimensions
■
•
Height: 40.6 mm
•
Width: 83.8 mm
•
Depth: 298.2 mm
AC model
Universal 100–240 V AC 50/60 Hz input
■
Maximum continuous current draw: 9 A at 85 V, 3.3 A at 230 V at full-rated
■
load
Maximum inrush surge current (cold start at 25º C/77º F): 34 A peak at
■
230 V
DC model
40V to 60V DC, 48V nominal
■
Supports either positive grounded or negative grounded operation
■
Maximum continuous current draw: 20A max at 40V DC
■
Maximum standby current: 300 mA
■
Run/Standby switch
■
Description
There is either a fan failure, or the temperature has exceeded
its limit of 70º C (158º F).
Description
A PSU is installed in the switch and is delivering power.
There is either a fan failure, or the temperature has exceeded
its limit of 70º C (158º F).