Installation; Location; Uncrating The Stand; Exterior Loading - Emerson Liebert GXT3 User Manual

Liebert gxt3 ups 230v 700va-3000va
Hide thumbs Also See for Liebert GXT3:
Table of Contents

Advertisement

Location

The refrigerated merchandisers have been designed for
use only in air conditioned stores where temperature and
humidity are maintained at or below 75°F and 55% relative
humidity. DO NOT allow air conditioning, electric fans,
ovens, open doors or windows (etc.) to create air currents
around the merchandiser, as this will impair its correct
operation.
Product temperature should always be maintained at a
constant and proper temperature. This means that from the
time the product is received, through storage, preparation
and display, the temperature of the product must be
controlled to maximize life of the product.

Uncrating the Stand

Place the fixture as close to its permanent position as
possible. Remove the top of the crate. Detach the walls from
each other and remove from the skid. Unbolt the case from
the skid. The fixture can now be lifted off the crate skid. Lift
only at base of stand!

exterior Loading

These models have not been structurally designed to
support excessive external loading. Do not walk on their
tops; This could cause serious personal injury and damage
to the fixture.

Setting and Joining

The sectional construction of these models enable them to
be joined in line to give the effect of one continuous display.
A joint trim kit is supplied with each joint.

Leveling

IMpORTAnT! IT IS IMpeRATIve THAT CASeS
Be LeveLeD FROM FROnT TO BACK AnD SIDe
TO SIDe pRIOR TO JOInInG. A LeveL CASe IS
neCeSSARY TO InSURe pROpeR OpeRATIOn,
WATeR DRAInAGe, GLASS ALIGnMenT, AnD
OpeRATIOn OF THe HInGeS SUppORTInG THe
GLASS. LeveLInG THe CASe CORReCTLY WILL
SOLve MOST HInGe OpeRATIOn pROBLeMS.
NOTE:
A. To avoid removing concrete flooring, begin lineup
leveling from the highest point of the store floor.
B. When wedges are involved in a lineup, set them first.
All cases were leveled and joined prior to shipment to
insure the closest possible fit when cases are joined in the
field. When joining, use a carpenters level and shim legs
accordingly. Case must be raised correctly, under legs
where support is best, to prevent damage to case.
1. Check level of floor where cases are to be set.
Determine the highest point of the floor; cases
will be set off this point.
2. Set first case, and adjust legs over the highest part of
the floor so that case is level. Prevent damage - case
must be raised under leg or by use of x6 or x4 leg
brace. Remove side and back leg braces after case
is set.

Installation

3. Set second case as close as possible to the first
case, and level case to the first using the instructions
in step one.
4. Apply masking tape 1/8" in from edge of case in base
and center air discharge. (See diagram).
5. Apply liberal bead of case joint sealant (butyl) to
dotted area shown in (Fig.2, #1) of first case. Apply
heavy amount to cover entire shaded area.
DO nOT USe peRMAGUM!
It is the contractor's responsibility to install
case(s) according to local construction and
6. Slide second case up to first case snugly, by using
alignment pins. Then, level second case to the first
case so that the bumper and plexiglass perimeters
line up.
7. To compress silicone at joint, use two Jurgenson
wood clamps. Make sure case is level from front to
back and side to side on inside bulkheads at joint.
8. Make sure cases are tightly joined together in the
appropriate locations (See diagram). Cases are
joined by turning the camlocks with the supplied
Allen wrench. This will lock the sections of the CIDM
together. Remove clamps after this has been done.
Do not use cam locks to pull cases together.
9. Apply bead of silicone to top of bulkheads and slip on
stainless steel bulkhead cap. Also apply silicone to
seam between overhead light tubes.
10. veRY IMpORTAnT! Apply liberal amounts of black
silicone to area under interior of pans and fill all
voids.
11. Use finger to smooth silicone as thin as possible at
masking tape on inside and outside of rear mullion
(apply additional silicone if necessary). Remove tape
applied on line #3.
4
IGIC-CIDM-0909
health codes

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents