Display parameter
pS
pASSWORD
/
pROBe pARAMeTeRS
/C
ambient probe calibration (x 0.1°C/°F)
/
Measurement stability
/4
probe display: 0 = regulation probe, 1 = product food probe (second probe)
/5
°C/°F (0=°C, 1=°F)
r
ReGULATOR pARAMeTeRS
rd
Regulating differential (hysteresis 0=0.5 °C/ °F)
r1
Minimum allowable set
r
Maximum allowable set Cr1 17 °C/°F 60
r3
Enabling Ed alarm: max duration of defrost is reached (0 = no, 1 = yes)
r4
Automatic variation of the Set-Point with closed curtain-switch (A4=4)
c
COMpReSSOR pARAMeTeRS
c0
Delay in the compressor start-up after switch-on
c1
Minimum time between two following compressor start-ups
c
Compressor shutdown minimum time
c3
Compressor operation minimum time
c4
Safety compressor (0 = OFF, 100 = ON)
cc
Continuous cycle duration
c6
Alarm delay after continuous cycle
d
DeFROST pARAMeTeRS
d0
defrost type (0 = heater, 1 = hot gas,  = time resistance, 3 = time hot gas)
d1
Time interval between two defrost cycles
dt
End defrost temperature
dP
Max defrost duration or effective duration if d0= or 3
d4
Defrost after start-up (0 = no, 1 = yes)
d5
Delay defrost after control Switch-On or from digital input (A4 or A5=4)
d6
Block temperature display during defrost (0 = no, 1 = yes)
dd
Dripping time after defrost
d8
Alarm delay after defrost
d9
defrost priority over compressor protection (0 = no, 1 = yes)
d/
Temperature defrost probe display
dC
Time base (0=hours/min, 1=min/s) Only for dl and dP
A
ALARM pARAMeTeRS
A0
Alarms and fans differential (0=0.5 °C/°F)
AL
Low temperature alarm (max. variation as to the Set-Point). AL=0 excluded Low temperature alarm
AH
High temperature alarm (max. variation as to the Set-Point). AH=0 excluded High temperature alarm
Ad
Temperature alarm delay
A7
Measurement delay time for the input "delayed alarm" (A4 or A5=)
F
FAn pARAMeTeRS
F0
Management of fans: 0=fans ON, specific phases excluded (F2, F3 and Fd) 1 = fans ON (dependent
on parameter F1) specific phases excluded
F1
Fan power on temperature
F
Fans OFF when the compressor is OFF (0 = no, 1 = yes)
F3
Fans OFF during defrost (0 = no, 1 = yes)
Fd
Stop after dripping ON for each F0 value
H
OTHeR SeLeCTIOnS
H0
Serial address
H1
Selection of the alarm relay operation 0=alarm ON, energized relay, 1= alarm ON, disenergized relay
H
0=disabled buttons, 1=enabled buttons
H5
Identification code for programming key (programmed by supervisor)
T
External parameter programming
*show the set value
NU*: not used parameter, leave the default value
Sporland Omnistat Time Clock program Settings (Cont'd)
please contact Sporlan valve Company for further information. www.sporIan.com
LIST OF pARAMeTeRS

IGIC-CIDM-0909
Type Min Max Unit Default
F
0
199
-

F
-17 17 °C/°F
0.0
C
1
15
-
4
C
0
1
flag
0
C
0
1
flag
0
F
0
19 °C/°F

C
-50
r °C/°F
-50
C
r1 17 °C/°F
60
C
0
1
flag
0
C
-0 0 °C/°F
3
C
0
15
min
0
C
0
15
min
0
C
0
15
min
0
C
0
15
min
0
C
0
100 min
0
C
0
15 hours
4
C
0
15 hours

C
0
3
flag
0
F
0
199 hours
8
F
-50 17 °C/°F
4
F
1
199 min
30
C
0
1
flag
0
C
0
199 min
0
C
0
1
flag
1
F
0
15
min

F
0
15 hours
1
C
0
1
flag
0
F
-
-
°C/°F
-
C
0
1
flag
0
C
0
19 °C/°F
0
F
0
17 °C/°F
0
F
0
17 °C/°F
0
C
0
199 min
0
C
0
199 min
0
C
0
1
flag
0
F
-50 17 °C/°F
5
C
0
1
flag
1
C
0
1
flag
1
F
0
15
min
1
C
0
199
-
1
C
0
1
flag
1
C
0
1
flag
1
F
-99 199
-
-
C
-99 99
-
0
value
CIDM
22
0.0
4
1
1
8
26°F
32°F
0
nU*
1
1
1
2
10
2
6
2
4
60
25
0
0
1
0
2
0
-
0
0
0
0
0
nU*
n/A
n/A
n/A
n/A
n/A
1
1
0
-
0