  • Page 1 CIDM-E CIDM-I p/n IGIC-CIDM-0909 INSTALLATION & OPERATION GUIDE...
  • Page 2: Table Of Contents

    IGIC-CIDM-0909 General Instructions Table of Contents This Booklet Contains Information on: General Instructions................2 CIDME / CIDMI Refrigerated Self-Service Island Display Cut and plan views ................3 Installation ................... 4 including 4’ Crown and 3’ Center Modules available as Location ......................4 standard refrigerated med temp.
  • Page 3: Cut And Plan Views

    Rev. 0909 Cut and plan views 29 1/2” 6” 9” 11” 3 11/16” 40 13/16” 3 11/16” 48 3/16” CIDM ISLAND CIDME CIDMI 3 1/16” 10’ 12 13/16” 30 3/8” 33’ 27’ 34 7/8” 36’...
  • Page 4: Installation

    IGIC-CIDM-0909 Installation Location 3. Set second case as close as possible to the first The refrigerated merchandisers have been designed for case, and level case to the first using the instructions use only in air conditioned stores where temperature and in step one.
  • Page 5: Joint Trim

    Rev. 0909 Installation (Cont'd) Joint Trim After cases have been leveled and joined, and refrigeration, Fasten using #8 self- electrical, and wasted piping work completed, install the drilling Phillips screws splashguards. Fasten along the top edge, or center, with #10 X 3/3” sheet metal screws. DO nOT SeAL JOInT TRIM TO FLOOR! After Joint Trim Seal to floor with NSF...
  • Page 6 IGIC-CIDM-0909 Installation (Cont'd) Boston Series 2000 Boston 2000 eco Series nOTe: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. nOTe: Rigid Top: Do not over cut. 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base.
  • Page 7 Rev. 0909 Installation (Cont'd) Boston 1000 Series b. Rigid Top: Snap the Rigid Top over the Rigid Base. nOTe: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. nOTe: Rigid Top: Do not over cut. Installation 3.
  • Page 8: Plumbing

    IGIC-CIDM-0909 plumbing Waste Outlet and p-TRAp 3. Always provide as much down hill slope (“fall”) as The waste outlet is located off the center of the case on possible; 1/8” per foot is the preferred minimum. one side allowing drip piping to be run lengthwise under PVC pipe, when used, must be supported to the fixture.
  • Page 9: Refrigeration

    Rev. 0909 Refrigeration Refrigerant Type Thermostatic expansion valve Location The standard refrigerant will be R- unless otherwise This device is located on the same side as the refrigeration specified on the customer order. Check the serial plate on stub. A Sporlan balanced port expansion valve model the case for information.
  • Page 10: Refrigeration Data

    IGIC-CIDM-0909 Refrigeration (Cont'd) Refrigeration Data Units with Slanted Shelves Refrigeration Data note: This data is based on store temperature and humidity that does not exceed 75F and 55% R.H. note: This data is based on store temperature and humidity Discharge Air (F) 26 that does not exceed 75F and 55% R.H.
  • Page 11: Electrical

    Rev. 0909 electrical Wiring Color Code appliances. It should be wired to a dedicated circuit. electrical Service Receptacles (When Applicable) The receptacles located on the exterior of the merchandiser are intended for scales and lighted displays. They are not intended nor suitable for large motors or other external appliances.
  • Page 12: User Information

    IGIC-CIDM-0909 Finishing Touches (Cont'd) 4. Apply cement with applicator to one or both Acrylic Cement surfaces. Join immediately. Plastic Rod 5. Apply just enough pressure to remove any air bubbles. Do not squeeze joint so hard as to force cement out of the joint - A dry joint may result. 6.
  • Page 13: Plexiglass And Acrylic Care

    Rev. 0909 User Information (Cont'd) Cleaning CAUTION Hussmann recommends using a clean damp chamois, or a paper towel marketed as dust and abrasive free with 210 ® plastic Cleaner and polish available by calling Sumner CLEANING PRECAUTIONS Labs at 1-800-542-8656. Hard, rough cloths or paper towels When cleaning: will scratch the acrylic and should not be used.
  • Page 14: Stainless Steel Cleaning And Care

    IGIC-CIDM-0909 Maintenance (Cont'd) Stainless Steel Cleaning and Care 3. Use Alkaline, Alkaline Chlorinated or There are three basic things, which can break down your non-chloride Containing Cleaners stainless steel’s passivity layer and allow corrosion. While many traditional cleaners are loaded with chlorides, the industry is providing an ever 1.
  • Page 15: Wiring Diagrams

    Rev. 0909 Wiring Diagrams...
  • Page 16 IGIC-CIDM-0909 Wiring Diagrams (Cont'd)
  • Page 17 Rev. 0909 Wiring Diagrams (Cont'd)
  • Page 18 IGIC-CIDM-0909 Wiring Diagrams (Cont'd)
  • Page 19 Rev. 0909 Wiring Diagrams (Cont'd)
  • Page 20 IGIC-CIDM-0909 Wiring Diagrams (Cont'd)
  • Page 21: Sporland Omnistat Time Clock Program Settings

    Rev. 0909 Sporland Omnistat Time Clock program Settings CID Mini With Omnistat Figure 2 Installer Information Reference Sheet Installers The CIDM has a Sporland Omnistat Time Clock that is factory programmed; therefore, the Setpoint and Defrost setting does not require setting (Omnistat is locked at factory and requires unlocking before setting) Start-up/Checklist 1.
  • Page 22 IGIC-CIDM-0909 Sporland Omnistat Time Clock program Settings (Cont'd) LIST OF pARAMeTeRS value Display parameter Type Min Max Unit Default CIDM pASSWORD pROBe pARAMeTeRS ambient probe calibration (x 0.1°C/°F) -17 17 °C/°F Measurement stability probe display: 0 = regulation probe, 1 = product food probe (second probe) flag °C/°F (0=°C, 1=°F) flag...
  • Page 23 Rev. 0909 Sporland Omnistat Time Clock program Settings (Cont'd) SAFeTY STAnDARD: in compliance with the european laws. Installation precautions • the connection cables should be suitable for up to 195°F operation; Caution: Low voltage and probe wiring must be properly separated from high voltage wiring DISpLAY During normal working conditions, the display shows the value measured by the air regulation probe or by the second probe (parameter /4).
  • Page 24: Mr4 Time Clock Program Settings

    IGIC-CIDM-0909 MR4 Time Clock program Settings programming the Control Use this section to program the control module. After programming, the control module reatins its programmed 3. Press Enter. The function's existing value settings, even in the event of power failure or power appears.
  • Page 25 Rev. 0909 MR4 Time Clock program Settings (Cont'd) Function Settings in Order of programming in Control Module Display Code Function Useable Setting Range and Unit value Factory-Set values None Setpoint -40 to 99°F (-40 to 80°C) Differential 1 to 9F° (1 to 9C°) 5 (F°) Low Setpoint Stop -40°F (-40°C) to High Setpoint Stop...
  • Page 26: Alarm And Fault Display Codes

    IGIC-CIDM-0909 MR4 Time Clock program Settings (Cont'd) Alarm and Fault Display Codes These alarm and fault codes flash on the LED display when the control detects the following faults. Table: Display Codes and Status Display Code Alarm or Fault Condition System Status Indicates an open or shorted main temperature Alarm is on.
  • Page 27 Rev. 0909 MR4 Time Clock program Settings (Cont'd) CIDM w/ MR4 Settings...
  • Page 28: Appendices

    IGIC-CIDM-0909 Appendices Appendix A. - Temperature Guidelines - Refrigerated 1. Refrigeration piping should be sized according to The refrigerators should be operated according to the the equipment manufacturer’s recommendations manufacturer’s published engineering specifications for and installed in accordance with normal refrigeration entering air temperatures for specific equipment applications.
  • Page 29: Appendix C. - Field Recommendations - Refrigerated

    Rev. 0909 Appendices (Cont'd) Appendix C. - Field Recommendations - Refrigerated d) OTHER OBSERVATIONS - Other Recommendations for field evaluating the observations should be made which may performance of retail food refrigerators and hot indicate operating problems, such as cases unsatisfactory product, feel/appearance.
  • Page 30: Appendix D. - Recommendations To User - Refrigerated

    IGIC-CIDM-0909 Appendices (Cont'd) 20. Has the equipment been modified 1.3 The best preservation is achieved by following these rules: to use replacements for CFC-1, CFC-50 or other refrigerant? If so, a) Buy quality products. have the modifications been made in b) Receive perishables from transit equipment accordance with the recommendations at the ideal temperature for the particular...
  • Page 31 IGIC-CIDM-0909 Service Record Last service date: _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ _______________ __________________________________________________________________________________________________ /Chino The MODEL NAME and SERIAL NUMBER is required in order to provide you with the correct parts and information for your particular unit. Additional copies of this publication may be obtained by contacting: They can be found on a small metal plate on the unit.