5 Technical Specifications

5.1 Power Supply Specifications

Power Supply Type
12 – 24 VDC
24 VDC
48 VDC
HI (125/250 VDC)
1
HI (110/230 VAC)
1
NOTES:
1. This is the same power supply for both AC and DC.
2. (F) Denotes fast-acting fuse, (T) denotes time-delay fuse
3. Power consumption varies based on configuration. 10/100Base-TX ports consume roughly
1W less than fiber optic ports
4. For continued protection against risk of fire, replace only with same type and rating of fuse.

5.2 Failsafe Relay Specifications

Parameter
Max Switching Voltage
Rated Switching Current
Max Switching Capacity

5.3 Networking Standards Supported

Parameter
IEEE 802.3
IEEE 802.3u
IEEE 802.3z
IEEE 802.3ab
IEEE 802.3x
IEEE 802.1D
IEEE 802.1Q
IEEE 802.1p
©
2008 RuggedCom Inc. All rights reserved
Input Range
Min
Max
10 VDC
36 VDC
18 VDC
36 VDC
36 VDC
59 VDC
88 VDC
300 VDC
85 VAC
265 VAC
240VAC, 125VDC
2A @ 240VAC
0.15A @ 125VDC, 2A @ 30VDC
150W, 500VA
10Mbps
100Mbps
Ports
Ports
26
Fuse
Rating
6.3A(F)
2
2
5A(F)
2A(T)
2
2A(T)
1,2
Value (Resistive Load)
1000Mbps
Ports
10BaseT / 10BaseFL
100BaseTX / 100BaseFX
Full Duplex Operation
VLAN (Virtual LAN)
Max. Power
3
Consumption
22W
Notes
1000BaseSX/LX
1000BaseTx
MAC Bridges
Priority Levels
Rev105