5.2
Specifications
Maximum associated cable loss
for EXTN. port
Port to port loss
Send and receive loudness
ratings on port to port basis
Extension (1AS) port
Port Type Classification
Extn. Port**
PSTN Port**
Paging Port (output)*
Ext. Music Port (input)*
Doorphone Port*
Door Opener Port
EIA (RS-232C) Port
Port Types between which Call Paths can be established
From
Extn.
PSTN
Paging
Ext. Music
Doorphone
Door Opener
EIA (RS-232C)
5-8
Appendix
PT: Max cable loss 0.34 dB (140 m max for ø 0.5 mm)
SLT: Max cable loss 0.87 dB (698 m max for ø 0.5 mm)
Loss across switch, PAS
Send loudness rating (1AS
Receive loudness rating (PAS
3 ringers can be supported with extension wiring up to 698 m.
Notes
• Extension ports 01 through 24 may be used for off premise extensions in which
case cabling would be required by BS 6701:Part 1 1986 to be equipped with
over voltage protection.
• When using separately approved extension telephones, the best overall
performance of the PBX system will be obtained by using extension telephones
of impedance class A clause 4.3.2.1. of BS 6305:1982.
Port Name
Connect to PT, SLT
Connect to Network
External Paging
External Music
Connect to KX-T30865
Door Opener
Connect to PC, Printer
* These ports do not respond to address signalling.
** These ports provide DTMF and Loop Disconnect Signalling.
To
Extn.
PSTN
A
A
X
A
A
X
X
1AS Loss=1.13 dB (Not through–fed system)
PAS)
1AS) : -6 dB (0km)
Brief Description
Ext.
Paging
Music
A
A
X
A
X
X
X
X
X
A
A
N/A
X
X
X
X
X
X
X
X
X
A: Allowed X: Not allowed N/A: Not applicable.
: +3dB (0km)
Port Type
1 AS
PAS
4F
4F
4E
4F
4E
Door-
Door
Phone
Opener
(RS-232C)
A
X
X
X
X
X
X
X
N/A
X
X
N/A
X
X
EIA
X
X
X
X
X
X
N/A