4.2
System Programming
[212] Exchange Line Duration Time Limit
Sets the maximum time allowed for a conversation with an external party. This program is
effective for the extension(s) which assigned "Enable" in program [613] "Exchange Line
Duration Time Limit Selection".
2
Default
• A beep sounds at 5-second intervals 15 seconds before the programmed time expires.
!
!
• This program is effective only for an outgoing outside call.
• When making a call after an exchange line is seized and transferred to the enabled
extension in program [613] by another extension, the timer starts after the call has been
transferred.
• Feature Reference
Section 3, Features
Limited Call Duration
[213] Bell Off Detection
Sets the maximum time between detecting one bell signal and the next from the Local
Exchange. In case the next bell signal is not detected within the programmed time, the
system recognises the bell signal has stopped.
2
Default
1
2
NEXT
10 minutes
1
3
NEXT
(3/6/12 sec)
3 seconds
time
STORE
(1··32 minutes)
STORE
SELECT
[212]-[213]
END
END
System Programming
4-31