Component Names and Functions

V640-HAM11-ETN and V640-HAM11-L-ETN Amplifier Units
No.
Name
1
Dedicated power supply con-
nector
2
Ethernet port
3
RUN indicator (green)
4
COMM indicator (yellow)
5
NORM indicator (green)
6
ERROR indicator (red)
7
CIDRW Head connection port A CIDRW Head is connected here.
8
Setting DIP switches
Connect to the 24 VDC power supply.
Connect to the host device through a LAN cable.
Turns ON when the Amplifier Unit is in normal operation.
Turns ON during communications with the host device or during communications with an
ID Tag.
Turns ON when the communications finish with no error.
Turns ON when an error occurs during communications with the host device, or during
communications with an ID Tag.
The V640-HS61 CIDRW Head is used with the V640-HAM11-ETN. The V640-HS62
CIDRW Head is used with the V640-HAM11-L-ETN.
Set the IP address and enable/disable the Test Mode with this DIP switch.
ACT(yellow)
LINK(green)
Product Outline
Function
LINK---lights while linking normally.
ACT---lights when detects a carrier.