Mutual Interference Distances (Reference Only)
If Amplifier Units are connected using multidrop connections and multiple CIDRW Heads are used, the
CIDRW Heads will not process commands simultaneously. In this case, install the CIDRW Heads at
least 0.1 m apart from each other.
Distance between Antennas and Changes in Communications Distances (Reference Only)
• V640-HS61
Distance between Antennas
1,000 mm
900 mm
800 mm
700 mm
600 mm
500 mm
400 mm
300 mm
200 mm
If CIDRW Heads in separate CIDRW systems process commands simultaneously when the CIDRW
Systems are installed close to each other, mutual interference between the Heads can result in mal-
functions. If this is a problem, install the CIDRW Heads separated at least by the distances shown in
the following illustrations.

■ For Coaxial Installation

• V640-HS61
1 m min.

■ For Parallel Installation

• V640-HS61
1 m min.
■ For Face-to-Face Installation
• V640-HS61
1 m min.
Change in communications distance
100%
100%
100%
99%
90%
74%
55%
40%
15%
• V640-HS62
• V640-HS62
• V640-HS62
Distance between Antennas
Change in communications distance
2,000 mm
99%
1,600 mm
99%
1,400 mm
95%
1,200 mm
84%
1,000 mm
68%
800 mm
53%
600 mm
34%
400 mm
15%
200 mm
0%
2 m min.
2 m min.
• V640-HS62
2 m min.