■ Host Communications Specifications
Item
Compliant standards
10Base-T and 100Base-TX
Protocol
TCP/IP
• If the IP address is set on the DIP switch, it will be in the form 192.168.1.@@@. The subnet mask
IP Address
is always 255.255.255.0
• The IP address of the Amplifier Unit can be either set on this DIP switch or the desired IP address
can be set in ROM. If pins 1 to 5 on the DIP switch are all turned OFF, the IP address that is set in
ROM will be used.
Default network settings
IP Address: 192.168.1.200, Subnet mask: 255.255.255.0
(Pins 1 to 5 on the DIP switch are all turned OFF)
Applicable port
TCP/IP: port 7090
MTU
1,500 bytes
Access to an Amplifier Unit is possible from only one host device at a time. If a host device (A) is connected to an Ampli-
fier Unit and another host device (B) connects to the Amplifier Unit, the connection between host device A and the
Amplifier Unit will be automatically broken and host device B will have the control right.
When the connection between a PC and a Amplifier Units have been disconnected, an Amplifier Unit can reopen com-
munication from a PC again by establishing a connection.
Communications with the ID Tag will be aborted if the Ethernet cable is disconnected or the connection is broken while
the Amplifier Unit is communicating with an ID Tag.