Interfaces

The following interfaces are available on the NWL-12 Series Router:
ITEM
Main antenna socket
Aux antenna socket
GPS antenna socket
Six-way terminal block
connector
Reset button
SIM card slot
RJ45 PoE Ethernet port
Mini USB 2.0 OTG port
Serial port
www.netcommwireless.com
Figure 4 - Interfaces
SMA female connector for main antenna.
SMA female connector for auxiliary antenna (receive diversity).
SMA female connector for an active GPS antenna.
Connect power source, ignition and I/O wires here. Power, ignition and I/O wires may be terminated on
optional terminal block and connected to DC input jack. Refer to the diagram and table under the
section for correct wiring of the terminal block. Operates in the 8-40V DC range.
Press and hold for less than 5 seconds to reboot to normal mode.
Press and hold for 5 to 15 seconds to reboot to recovery mode.
Press and hold for 15 to 20 seconds to reset the router to factory default settings.
Insert SIM card here.
Connect one or several devices via a network switch here. This port can also optionally receive Power over
Ethernet (802.3af PoE) in which case the DC power supply can serve as a backup power source if required
(PoE available on NWL-12-01 only).
Provides connectivity for optional external storage or a USB Ethernet dongle. Supplies up to 0.5A to
connected device.
Female DB9 port supporting 9-wire RS-232, RS-485 or RS-422 (software selectable).
Table 6 – Interfaces
DESCRIPTION