60
en | Advanced configuration menu
6.1.3

Time Server

Automatic time synchronization (done once every four days) can only change the clock by a
maximum of 10 minutes (see Note under Section 6.1.2 Time/date).
6.2
Video & Audio
Use this menu to configure the video and audio inputs. Remember, for hybrid units with 8
analog input channels, IP cameras are numbered from 9 to 16; for 16-channel hybrid units, IP
cameras are numbered from 17 to 32. For the digital network recorder which does not have
analog inputs, IP camera numbers begin at 1.
6.2.1

Analog Channels

The tabs 1-8 or 1-16 across the top of the menu contain the settings for each of the analog
inputs on a digital hybrid recorder.
Figure 6.3 Configuration menu - Video & Audio - Analog camera
Input name
Enter a name for the selected input. The name can be up to 16 characters long.
Enable video input
This setting enables (default) or disables the video and corresponding audio inputs.
F.01U.140.955 | v3.0 | 2009.11
The Use time server function synchronizes the time of the unit with the time of a network
time server or another Divar unit. Fill in the IP address of the network time server. If a
time server is not present on the same subnet, the unit searches for a suitable time
server outside its own network. Make sure the Divar gateway is set correctly to find the
time server. Ensure that firewalls do not block NTP traffic via port 123.
Click Synchronize to start time synchronization.