Contacts

Use the Contacts menu to set up alarm inputs and relay outputs.
Figure 6.7 Configuration menu - Contacts
6.5.1

Contact inputs

By default, all contact Inputs are Normally Open (NO). When needed, highlight contact inputs
to function as Normally Closed (NC) contacts (highlight the un-numbered box to select all).
6.5.2

Relay outputs

By default, all relay output contacts are Normally Open (NO). When needed, highlight the relay
outputs to function as Normally Closed (NC) contacts.
6.5.3

Contact input properties

Each of the 16 contact inputs can be assigned a name and a profile override mode.
Profile overrides
An alarm input can activate a profile override. There are three modes available:
When a profile override is selected, choose which Profile of the six will be used as the
override profile and then set the override Duration.
Bosch Security Systems
No override (default)
Follows: the profile override lasts for as long as the input is active (no override duration
can be set).
Fixed duration: the profile override starts when the input becomes active and continues
for the time set in the override duration field.
Installation and Operation manual
Advanced configuration menu | en
F.01U.140.955 | v3.0 | 2009.11
67