Imaging Unit Life Messaging

The following table provides the messaging that will appear on the Control Panel as supply life becomes
low. Below the table, explanations are provided for the headings and options listed in each column.
Life Cycle
Default
State
Setting
Nearly Low
Disabled
Low
Enabled
Near End
Enabled
of Life
End of Life
Enabled
Device Stops
1
This column indicates the default Imaging Unit life remaining. Once the Imaging Unit reaches this percentage, it will trigger the
given warning. The user can change the level that will trigger the warning. The procedures to do this are documented in this
guide in the section called "How to Change Supply Life Messaging Settings."
2
This column lists the default behavior options at each warning notification. The customer can customize this feature. The
default behavior is documented in
3
The estimated number of remaining pages is based on recent printing history of the printer. Its accuracy may vary significantly
and is dependent on many factors, such as actual document content, print quality settings, and other printer settings. The
accuracy of the estimated number of remaining pages may decrease when actual printing consumption is different from the
historical printing consumption. Consider the variable level of accuracy before purchasing or replacing supplies based upon the
estimate. Until an adequate print history is obtained on the printer, initial estimates assume future supplies consumption based
on the International Organization for Standardization* test methods and page content.
*Average continuous black declared cartridge yield in accordance with ISO/IEC 19752.
For Training Purposes Only
Control Panel Message
Imaging unit nearly low [84.xy]
Imaging unit low [84.xy]
Imaging unit very low
3
[X]
estimated pgs remain [84.xy]
Page by page countdown begins.
Replace imaging unit,
3
0
estimated pgs remain [84.xy]
blue
if no change is made.
55
Default Trip
Behavior Options
1
Point
(Default in Blue)
Off
Warning
100K = 10%
E-mail alert
Continuable stop
Non-continuable stop
Off
Warning
100K = 5%
E-mail alert
Continuable stop
Non-continuable stop
Off
Warning
100K = 1%
E-mail alert
Continuable stop
Non-continuable stop
0%
Non-continuable stop