Testing The Remote Display; Display; Digital Outputs; Digital Inputs - Rice Lake LaserLight Installation & Operation Manual

4-sg led remote displays
Table of Contents

Advertisement

3.4

Testing the Remote Display

The
LaserLight
remote display provides a test to check the hardware of the remote display. These tests can be
accessed through the main menu (Figure 3-7).
3.4.1

Display

When this feature is enabled, all LEDs remain lit until the
3.4.2

Digital Outputs

When enabled, this feature provides a way to view the different states of the digital outputs or the stop/go option
if installed.Use left and right arrows to increment/decrement and display the states LL, LH, HL, and HH which
are digital values of the 2 ports.
The following table lists the relay terminology and digital signal level terminology of each command.
Press the right button again to display LL and the stop/go option will show no light at all.
Press the right button again to display LH and the stop/go option will show a green arrow.
Press the right button again to display HL and the stop/go option will show a green circle.
So when HH is selected, the stop/go option will show a red circle.
3.4.3

Digital Inputs

When enabled, the digital inputs displays the current values read from the digital inputs.
SERIAL
CONFIG
TEST
DISPLY
LL-OFF
Figure 3-7. Test Menu Choices
Dig out 1
Dig out 0
L
L
H
H
Relay On/Off Terminology
VER
DIGOUT
DIGIN
XX
LH-
HH-red circle
grn arrow
HL-grn circle
button is pressed (Figure 3-2 on page 11).
ENTER
Stop/Go Signal
L
Off
Green arrow on
H
L
Green circle on
Red stop
H
L = ON = 0V
H = OFF = +5V
Table 3-7.
LOOP BK
Configuration
19