Brother MFC620CN Service Manual page 418

Hide thumbs Also See for MFC620CN:
Table of Contents

Advertisement

Selector
No.
1
Not used.
2
3
|
Masking of symbol rate(s)
8
NOTE: WSW40 takes effect only when the V.34 mode is permitted (WSW19, selector 7) in models
supporting V.34 mode.
Selectors 3 through 8:
These selectors allow you to limit the transmission speed range in V.34 mode by masking the
desired symbol rate(s). Transmission speeds assigned to the symbol rates are listed on the next page.
The setting made by these selectors will limit the setting made by selectors 1 through 4 of WSW39.
If selector 3 is set to "1" to mask the 3429 symbols/second when the first transmission speed choice
is 33600 bps (specified by selectors 1 through 4 of WSW39), for example, then the allowable
maximum transmission speed will be limited to 31200 bps. If selector 8 is set to "1" to mask the
2400 symbols/second when the first transmission speed choice is 33600 bps, then the allowable
maximum transmission speed remains 33600 bps.
If selector 8 is set to "1" to mask the 2400 symbols/second when the first transmission speed choice
is 21600 bps (specified by selectors 1 through 4 of WSW39), then the allowable maximum
transmission speed remains 21600 bps but the minimum transmission speed will be limited to 4800
bps.
WSW40
(V.34 modem settings)
Function
Masking of symbol rate(s)
App. 4-43
Setting and Specifications
Not masking
Masking
No. 3
0
No. 4
0
No. 5
0
No. 6
0
No. 7
-
No. 8
0
1
3429 symbols/sec
1
3200 symbols/sec
1
3000 symbols/sec
1
2800 symbols/sec
-
Not used.
1
2400 symbols/sec