Selector
No.
1
Redial interval
2
3
|
No. of redialings
6
7
Not used.
8
CRP option
Selectors 1 through 6:
The machine redials by the number of times set by selectors 3 through 6 at intervals set by selectors
1 and 2.
Selector 8:
CRP option
If a command error occurs in the machine (calling station), the machine usually waits for three
seconds and then makes a retry three times. This CRP option is a request command that can be sent
from the called station for requesting the calling station to retry the failed command immediately.
WSW15
(REDIAL facility setting)
Function
Redial interval and No. of redialings
App. 4-18
Setting and Specifications
No. 1
2
0
0
:
5 minutes
0
1
:
1 minute
1
0
:
2 minutes
1
1
:
3 minutes
No. 3
4
5
6
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
|
1
1
1
1
0: Disable
:
16 times
:
1 times
:
2 times
:
3 times
|
:
15 times
1: Enable
Confidential