Brother MFC620CN Service Manual page 427

Hide thumbs Also See for MFC620CN:
Table of Contents

Advertisement

Selector
No.
Percentage voltage for
interpreting the external
1
telephone as being hooked up
2
(based on the network's standard
voltage)
DC mask curve table to be
3
applied when the line is
connected
AC impedance to be applied
4
when the line is connected
Current control to be applied
5
immediately after
6
connection of the line
7
AC voltage threshold for
8
detection of ring
NOTE: WSW50 is applicable to models equipped with SDAA circuits.
Selectors 5 and 6: Current control to be applied immediately after connection of the line
FAX models equipped with an SDAA circuit (on which an NTU chip is mounted) might not be
connected to a broad band line such as an ADSL (Asynchronous Digital Subscriber Line) in a
stable condition. If those models fail to connect to such a line, try to change the current control to
be applied immediately after connection of the line by using selectors 5 and 6.
If selectors 5 and 6 are set to "0" and "1," respectively, the SDAA draws more current, decreasing
the period required to terminate the current control. If they are set to "1" and "0," the SDAA finely
controls precision of the termination current against the voltage to approach nearer to the specified
DC curve that specifies the current vs. voltage characteristics of the network termination. Selecting
either control may solve an unstable connection problem.
WSW50
Function
App. 4-52
(SDAA settings)
Setting and Specifications
No. 1 2
0 0 :
50%
0 1 :
80%
1 0 :
30%
1 1 : No detection
0:
Apply the initial value specified by local
regulations
1:
Apply table DC5 prepared specially
0:
600Ω termination
1:
ZR termination
No. 5 6
0 0 : Standard
0 1 : Increase start-up current for
termination
1 0 : Fine current control for termination
1 1 : Not used. (equal to "0, 0")
No. 7 8
0 0 : 19 V
0 1 : 11 V
1 0 : 25 V
1 1 : 31 V