Recording System Check; Preparations For Recording; Ic301 Trx (Rf) Bist Check; Processing After Completing Recording System Check - Sony DCR-TRV6 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-TRV6:
Table of Contents

Advertisement

2. Recording System Check

2-1. Preparations for recording

1)
Playback the BIST check tape.(XH5-6(NTSC), XH5-6P(PAL))
2)
Select page: 3, address: 10, set data: C0, and press the PAUSE
button.
3)
Select page: 3, address: 11, set data: 07, and press the PAUSE
button.
4)
Enter the stop mode.
5)
While keep the HOLD switch of the adjustment remote
commander at ON(SERVICE) position, eject the BIST check
tape and close the cassette compartment without inserting a
cassette.
6)
Set the power switch to "CAMERA".
7)
Select page: 3, address: 01, set data: 0C, and press the PAUSE
button.

2-2. IC301 TRX (RF) BIST Check

1)
Select page: 3, address: 70, set data: 04, and press the PAUSE
button.
2)
Select page: 3, address: 70, set data: 00, and press the PAUSE
button.
3)
When the IC301 TRX (RF) recording system from is normal,
the display data (combination data) of page: 3, address: 71 and
72 agrees with any combination as shown below.
NTSC model
Address
Data
71
26
5E
72
95
E3
PAL model
Data
Address
71
53
77
72
DF
D5
2-3. Processing after Completing Recording System
Check
1)
Select page: 3, address: 01, set data: 00, and press the PAUSE
button.
2)
Turn off the power and turn on again.
5-59