10. Optical Axis Adjustment
(DCR-TRV6/TRV6E/TRV11/TRV11E)
Align the lens Optical Axis with that of the CCD imager. If deviated,
center of picture can lose focus when zoom is operated from the
WIDE end to the TELE end.
Subject
Siemens star
Measurement Point
Check on the monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
69
Switch setting:
1) POWER .................................................................. CAMERA
Preparations before adjustments:
1) Playback the monoscope segment of the system check tape
(XH5-5 (NTSC), XH5-5P (PAL)).
2) Attach the optical axis frame chart (transparent) on the monitor
TV screen. Center of monoscope image and that that of optical
axis frame must be agree.
3) Set to the camera mode.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 40, and set data: 02.
3) Select page: 6, address: 41, and set data: 01.
4) Input the data of Table 5-1-9 to each adjustment addresses.
Note: Press the PAUSE button each time to set the data.
Page: F
Address: 69
Address: D0
NTSC
00
22
Table. 5-1-10.
5) Place the Siemens star 2.0 m away from the front of the lens.
6) Shoot the Siemens star with the zoom TELE end.
7) Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
8) Shoot the Siemens star with the zoom WIDE end.
9) Measure on the monitor TV screen in which area of the optical
axis frame the center of the Siemens star is located. Measure
the amount of displacement (distance between the center of
the Siemens star and the center of the optical axis frame.) The
measurement value is named L1.
10) Read the correction data corresponding to the area from Table
5-1-10.
11) Input the correction data to each adjustment address.
Note: Press the PAUSE button each time to set the data.
12) Shoot the Siemens star with the zoom TELE end.
13) Point the lens toward the Siemens star chart until center of the
Siemens star is located in the center of the optical axis frame.
14) Shoot the Siemens star with the zoom WIDE end.
15) Measure the amount of displacement (distance between the
center of the Siemens star and the center of the optical axis
frame.) The measurement value is named L2.
16) Compare the values L1 and L2, and confirm that L2 is smaller
than L1. If L2 is lager than L1, input the data of Table 5-1-9 to
each adjustment address.
Note: Press the PAUSE button each time to set the data.
E
D0, DE
Page: E
Address: DE
PAL
NTSC
PAL
26
5F
71
Note: NTSC model: DCR-TRV6/TRV11
PAL model: DCR-TRV6E/TRV11E
Display
Area
phase
1
22.6 to
67.5
2
67.6 to
112.5
3
112.6 to
157.5
4
157.6 to
202.5
5
202.6 to
247.5
6
247.6 to
292.5
7
292.6 to
337.5
8
337.6 to
22.5
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
2) Select page: 6, address: 40, and set data: 00.
3) Select page: 6, address: 41, and set data: 00.
5-26
Connection data
Page: F
Page: E
Address: 69
Address: D0
Address: DE
NTSC PAL
NTSC PAL
01
22
26
02
22
26
03
22
26
04
02
26
05
22
26
06
22
26
07
22
26
08
02
26
Table. 5-1-11.
Fig. 5-1-8.
57
69
5F
71
67
79
69
7D
67
79
5F
71
57
69
55